6 - 14 MC3000 Integrator Guide
Transmission
checksum error
-11 An error occurred during transmission from the source device (either radio
card or serial port) and the checksum check failed. Check source device
connectivity and retry.
Readback checksum
error
-12 A checksum, generated from reading back data that was written to the
destination device, was incorrect. An error during transmission or a write
error to the destination device could cause this.
There is no more heap
space available
-14 There is no more heap space available for the download procedure. Restart
IPL and retry the download. If the failure persists, contact service with details
of what is being downloaded.
Insufficient data
available to complete
record
-21 A Symbol HEX file download was attempted but the HEX file is invalid.
Ensure the file is in Symbol HEX file format.
Invalid Symbol HEX file -23 A Symbol HEX file download was attempted but the HEX file is invalid.
Ensure the file is in Symbol HEX file format.
Unrecognized or
unsupported HEX
record
-24 The Symbol HEX file being downloaded contains an invalid or unrecognized
HEX record. Ensure the file is in proper Symbol HEX file format.
Invalid data in HEX file -25 The Symbol HEX file being downloaded contains invalid data. Ensure the file
is in proper Symbol HEX file format with valid HEX data.
Exceeded max size -26 The download file is too large to fit into the space allocated for it. Either make
the file smaller or increase the space allocated for it by altering the partition
table.
Partition is not valid on
this device
-27 The downloaded file specifies a partition entry that does not exist on the
device. Only download files that are valid for this device, or change the
partition table so that the new file is valid on the device.
Wrong destination
code
-28 A specific partition was chosen from the IPL main menu (not Auto Select) but
the file selected for download was for another partition. Ensure that the
partition selected from the IPL main menu matches the file selected for
download.
File type does not
support IPL Auto
Select
-29 Monitor, Power Micro and Partition Table cannot be loaded with Auto Select.
Select the appropriate area, and try again.
Non-contiguous record
found
-30 A Symbol HEX file download was attempted but the HEX file is invalid.
Ensure the file is in Symbol HEX file format.
Timed Out - No data -31 IPL was waiting for data from the source device but timed out before
receiving any. Check the source device connectivity and retry.
Table 6-4 IPL Errors (Continued)