SG2440
Telecommunications Optical Node
Installation and Operation Manual
4
2
7
IN
6
STARLINE
®
Przeglądanie stron 0
1 2 3 4 5 6 ... 88 89

Podsumowanie treści

Strona 1 - STARLINE

SG2440Telecommunications Optical NodeInstallation and Operation Manual427IN6STARLINE®

Strona 2

1-2 Introduction SG2440 Installation and Operation Manual Figure 1-2 illustrates an open SG2440 telecommunications optical node: Figure 1-2 SG2440

Strona 3

Introduction 1-3 SG2440 Installation and Operation Manual  Optional LIFELINE™ status monitoring  User-friendly fiber management  60/90 volt

Strona 4 - Contents

1-4 Introduction SG2440 Installation and Operation Manual Document Conventions Before you begin to use the SG2440, familiarize yourself with the st

Strona 5 - Installation

Introduction 1-5 SG2440 Installation and Operation Manual 4 Ship the unit PREPAID to the following address: Motorola, Inc. Broadband Communicati

Strona 6 - Figures

SG2440 Installation and Operation Manual Section 2 Overview The SG2440 is a major upgrade of the capabilities of the SG2000 telecommunications opti

Strona 7

2-2 Overview SG2440 Installation and Operation Manual Housing The SG2440 optical node is furnished in an aluminum housing that protects the electro

Strona 8 - Contents v

Overview 2-3 SG2440 Installation and Operation Manual Port Locations Six housing ports provide connection for coaxial cables. Housing Port 2 and

Strona 9 - Introduction

2-4 Overview SG2440 Installation and Operation Manual Gaskets Each housing is equipped with a woven-wire RF gasket and a silicone-rubber gasket to

Strona 10 - SG2440 — open

Overview 2-5 SG2440 Installation and Operation Manual Network Monitoring The optional LIFELINE Status Monitoring System enables you to monitor th

Strona 11 - Related Documentation

2-6 Overview SG2440 Installation and Operation Manual Model Description Function SG2-PS Power supply Provides the +24 V and +5 V dc supply to th

Strona 12 - Calling for Repairs

CautionCautionCautionCaution These servicing instructions are for use by qualified personnel only. To reduce the risk of electrical shock, do not

Strona 13 - Introduction 1-5

Overview 2-7 SG2440 Installation and Operation Manual Return Band Return band configurations utilize up to two optical transmitters in the follow

Strona 14 - Overview

2-8 Overview SG2440 Installation and Operation Manual Figure 2-4 provides a diagram of the signal flow-path through the SG2440: Figure 2-4 Signal

Strona 15 - Housing

Overview 2-9 SG2440 Installation and Operation Manual Configuration You can order the SG2440 in a number of configurations to suit system require

Strona 16 - Port Locations

2-10 Overview SG2440 Installation and Operation Manual The following subsections present the options in the same left-to-right sequence as the cons

Strona 17 - Gaskets

Overview 2-11 SG2440 Installation and Operation Manual Bandpass Frequency Splits (SG2440-X*) The SG2440 is configured with sufficient frequency b

Strona 18 - Options and Accessories

2-12 Overview SG2440 Installation and Operation Manual Figure 2-7 illustrates the tilt selection chart for 750 MHz bandwidth: Figure 2-7 Relative

Strona 19 - Electronics Package

Overview 2-13 SG2440 Installation and Operation Manual RF Configuration (SG2440-XXX-*) The SG2440 is configured with four active RF outputs (Key

Strona 20 - Return Band

2-14 Overview SG2440 Installation and Operation Manual Forward Path Padding The pad values presented in Table 2-2 serve as a starting point referen

Strona 21 - Signal flow diagram

Overview 2-15 SG2440 Installation and Operation Manual Level Control (SG2440-XXX-XX*) The SG2440 is configured with a temperature compensation un

Strona 22 - Configuration

2-16 Overview SG2440 Installation and Operation Manual Figure 2-10 illustrates the SG2-PS power supply: Figure 2-10 SG2-PS power supply SG2-PSASSE

Strona 23 - 2-10 Overview

FCC ComplianceFCC ComplianceFCC ComplianceFCC Compliance This equipment has been tested and found to comply with the limits for a Class A digital d

Strona 24 - Station Tilt (SG2440-XX*)

SG2440 Installation and Operation Manual Section 3 Bench Setup and Operation Before you install the SG2440, it must be set-up to meet the power and

Strona 25 - Figure 2-7

3-2 Bench Setup and Operation SG2440 Installation and Operation Manual To facilitate on-line replacement on SG2440s equipped with redundant power s

Strona 26 - Overview 2-13

Bench Setup and Operation 3-3 SG2440 Installation and Operation Manual SG2440 forward-path configuration options include: Key 8 Forward Path Con

Strona 27 - Reserve gain set for 2 dB

3-4 Bench Setup and Operation SG2440 Installation and Operation Manual Figure 3-4 illustrates the plug-in board required for the standard-forward,

Strona 28 - Overview 2-15

Bench Setup and Operation 3-5 SG2440 Installation and Operation Manual Standard Forward Redundant In the standard forward redundant configuration

Strona 29 - SG2-PS power supply

3-6 Bench Setup and Operation SG2440 Installation and Operation Manual Figure 3-7 illustrates the JP2 suitcase jumper located on the lid motherboar

Strona 30 - Bench Setup and Operation

Bench Setup and Operation 3-7 SG2440 Installation and Operation Manual 11 Move JP2 to the B override position, which turns receiver A off. 12 Re

Strona 31 - Forward Path Configuration

3-8 Bench Setup and Operation SG2440 Installation and Operation Manual 3 Ensure that the PIC cable is properly connected to the lid and E-pack conn

Strona 32 - Standard Forward

Bench Setup and Operation 3-9 SG2440 Installation and Operation Manual Frequency Band Split and Frequency Band Split with Redundancy In the frequ

Strona 33

3-10 Bench Setup and Operation SG2440 Installation and Operation Manual To set up the frequency band split and frequency band split with redundancy

Strona 34 - Standard Forward Redundant

SG2440 Installation and Operation Manual Contents Section 1 Introduction Using this Manual ...

Strona 35

Bench Setup and Operation 3-11 SG2440 Installation and Operation Manual Return Path Configuration The following subsections present information t

Strona 36 - Forward Segmented

3-12 Bench Setup and Operation SG2440 Installation and Operation Manual SG2440 return-path configuration options include: Key 9 Return Path Config

Strona 37

Bench Setup and Operation 3-13 SG2440 Installation and Operation Manual Figure 3-14 illustrates the plug-in board required for the single combine

Strona 38 - Frequency band split board

3-14 Bench Setup and Operation SG2440 Installation and Operation Manual Split Return with Analog and 1X Digital Transmitters In the split return co

Strona 39

Bench Setup and Operation 3-15 SG2440 Installation and Operation Manual 5 Verify that the green LED (ON), located on the top panel of the transmi

Strona 40 - Return Path Configuration

3-16 Bench Setup and Operation SG2440 Installation and Operation Manual Figure 3-18 provides greater detail of the DS-SG2-DRT-2X/A second RF input

Strona 41

Bench Setup and Operation 3-17 SG2440 Installation and Operation Manual Split Redundant Return with 2X Digital Transmitters In the split return w

Strona 42

3-18 Bench Setup and Operation SG2440 Installation and Operation Manual Figure 3-21 illustrates the two DS-SG2-DRT-2X/A transmitters installed in t

Strona 43

Bench Setup and Operation 3-19 SG2440 Installation and Operation Manual Segmented Return with 2X Digital Transmitters In the segmented return con

Strona 44

3-20 Bench Setup and Operation SG2440 Installation and Operation Manual 5 Refer to Section 4, “Optical Modules,” for instructions on 2X Digital Tra

Strona 45 - Second RF input cable

ii Contents SG2440 Installation and Operation Manual Single Combined and Redundant Single Combined Return...

Strona 46 - Figure 3-20

Bench Setup and Operation 3-21 SG2440 Installation and Operation Manual Powering the Node You can conveniently power the SG2440 by applying 60 Va

Strona 47 - DRT 2 cable

3-22 Bench Setup and Operation SG2440 Installation and Operation Manual In addition to providing overcurrent protection, fuse locations also determ

Strona 48

Bench Setup and Operation 3-23 SG2440 Installation and Operation Manual Table 3-1 identifies and describes the ac fuse options: Table 3-1 AC fuse

Strona 49

3-24 Bench Setup and Operation SG2440 Installation and Operation Manual The dc supply can deliver 4.3 A at +24 V and 0.85 A at +5 V. Test points ar

Strona 50 - Powering the Node

Bench Setup and Operation 3-25 SG2440 Installation and Operation Manual Other power configurations are possible, but not recommended. CAUTION! T

Strona 51

SG2440 Installation and Operation Manual Section 4 Optical Modules This section identifies and provides detailed information on the forward and ret

Strona 52 - Power Supply Settings

4-2 Optical Modules SG2440 Installation and Operation Manual Removing SG2440 Optical Modules The SG2440 optical modules design enables you to remov

Strona 53 - Secondary ac

Optical Modules 4-3 SG2440 Installation and Operation Manual SG2-R/* Optical Receiver The SG2-R/* is a line of forward-path optical receivers use

Strona 54

4-4 Optical Modules SG2440 Installation and Operation Manual Figure 4-2 illustrates the SG2-R/* receiver: Figure 4-2 SG2-R/* HYBRIDCURRENT(1 V/A)O

Strona 55

Optical Modules 4-5 SG2440 Installation and Operation Manual The wavelength selection jumper is factory-set and provides optimum calibration in a

Strona 56 - 4-2 Optical Modules

Contents iii SG2440 Installation and Operation Manual Appendix A Specifications Appendix B Torque Specifications Abbreviations and Acronyms Figur

Strona 57 - SG2-R/* Optical Receiver

4-6 Optical Modules SG2440 Installation and Operation Manual Figure 4-4 illustrates the relationship between test-point voltage (Vdc) and optical p

Strona 58 - Feature Description

Optical Modules 4-7 SG2440 Installation and Operation Manual SG2-FPT Optical Transmitter The SG2-FPT is a non-isolated Fabry-Perot return-path op

Strona 59 - Optical Receiver

4-8 Optical Modules SG2440 Installation and Operation Manual SG2-EIFPT Optical Transmitter The SG2-EIFPT (illustrated in Figure 4-6) is an enhanced

Strona 60 - Figure 4-4

Optical Modules 4-9 SG2440 Installation and Operation Manual SG2-DFBT Optical Transmitter The SG2-DFBT is an isolated distributed feedback (DFB)

Strona 61 - SG2-FPT Optical Transmitter

4-10 Optical Modules SG2440 Installation and Operation Manual SG2-DFBT/3 Optical Transmitter The SG2-DFBT/3 is an isolated distributed feedback (DF

Strona 62 - 4-8 Optical Modules

Optical Modules 4-11 SG2440 Installation and Operation Manual DS-SG2-DRT/A Digital Return Transmitter The DS-SG2-DRT/A is an SG2 return transmitt

Strona 63 - SG2-DFBT Optical Transmitter

4-12 Optical Modules SG2440 Installation and Operation Manual Table 4-7 provides information on the user-related features of the DS-SG2-DRT/A trans

Strona 64 - 4-10 Optical Modules

Optical Modules 4-13 SG2440 Installation and Operation Manual DS-SG2-DRT-2X/A Digital Return Transmitter The DS-SG2-DRT-2X/A is an SG2 return tra

Strona 65 - 1310 DFB

4-14 Optical Modules SG2440 Installation and Operation Manual Table 4-8 provides information on the user-related features of the DS-SG2-DRT-2X/A: T

Strona 66

Optical Modules 4-15 SG2440 Installation and Operation Manual Figure 4-13 illustrates the DS-SG2-DRT-2X/A installed in the SG2440 with completed

Strona 67 - Figure 4-12

iv Contents SG2440 Installation and Operation Manual Figure 3-18 DS-SG2-DRT-2X/A cable connector ...

Strona 68

4-16 Optical Modules SG2440 Installation and Operation Manual Status Monitoring Table 4-9 identifies and describes the status monitor provisions bu

Strona 69 - Figure 4-13

Optical Modules 4-17 SG2440 Installation and Operation Manual Manual Control Board The SG2440 manual control board (SG2-MCB) serves to locally co

Strona 70 - Status Monitoring

4-18 Optical Modules SG2440 Installation and Operation Manual Description Function Potentiometers ICS1 through ICS4 Control the attenuation of th

Strona 71 - Manual Control Board

Optical Modules 4-19 SG2440 Installation and Operation Manual Ingress Control The SG2440 platform incorporates electronic ingress control switchi

Strona 72 - Description Function

SG2440 Installation and Operation Manual Section 5 Installation Installation consists of splicing the six-fiber service cable to the transportation

Strona 73 - Ingress Control

5-2 Installation SG2440 Installation and Operation Manual 3 Assemble the splice enclosure following the instructions furnished with the enclosure.

Strona 74

Installation 5-3 SG2440 Installation and Operation Manual Strand Wire Mounting Two strand clamps and bolt assemblies are located on a bracket att

Strona 75 - 5-2 Installation

5-4 Installation SG2440 Installation and Operation Manual Figure 5-3 Mounting bracket-rear and side views 34 OUT12IN637 82145 To mount the housing

Strona 76 - Strand Wire Mounting

Installation 5-5 SG2440 Installation and Operation Manual Figure 5-4 illustrates the dimensions of the center conductor: Figure 5-4 Center condu

Strona 77 - 5-4 Installation

5-6 Installation SG2440 Installation and Operation Manual 3 Carefully dress the excess fiber into the ramp of the fiber spool tray. Wrap the fiber

Strona 78 - Fiber Cables

Contents v SG2440 Installation and Operation Manual Table 4-4 SG2-EIFPT features...

Strona 79 - 5-6 Installation

Installation 5-7 SG2440 Installation and Operation Manual 5 Position the fiber service cable in the compression fitting to provide some slack in

Strona 80 - Installation 5-7

SG2440 Installation and Operation Manual Appendix A Specifications Specifications for the SG2440 are valid over the given bandpass and operating te

Strona 81

A-2 Specifications SG2440 Installation and Operation Manual Table A-3 lists the general characteristics for the SG2440 node: Table A-3 SG2440 gene

Strona 82 - A-2 Specifications

Specifications A-3 SG2440 Installation and Operation Manual Table A-6 lists the RF performance specifications for the SG2-FPT laser transmitter:

Strona 83 - Specifications A-3

A-4 Specifications SG2440 Installation and Operation Manual Table A-9 lists the RF performance specifications for the SG2-EIFPT laser transmitter:

Strona 84 - Parameter Specification

Specifications A-5 SG2440 Installation and Operation Manual Table A-11 lists the RF performance specifications for the SG2-DRT-2X/A digital retu

Strona 85 - Specifications A-5

SG2440 Installation and Operation Manual Appendix B Torque Specifications Torque specifications are valid for all models of the SG2440 node. Torqu

Strona 86

SG2440 Installation and Operation Manual Abbreviations and Acronyms The abbreviations and acronyms list contains the full spelling of the short fo

Strona 87

Abbreviations and Acronyms-2 SG2440 Installation and Operation Manual OMI optical modulation index P-V Peak-to-valley pA picoampere PIC power interc

Strona 89 - 495166-001

SG2440 Installation and Operation Manual Section 1 Introduction Motorola’s STARLINE® SG2440 scaleable optical node is the successor to the popular