Podsumowanie treści

Strona 1 - INTEGRATOR GUIDE

MP6000INTEGRATOR GUIDE

Strona 2

viii MP6000 INTEGRATOR GUIDEScale Zero Button (Configurations with Scale Only) ... 5-4Volume/T

Strona 3

3 - 14 MP6000 INTEGRATOR GUIDEFigure 3-13 Scale Display - Base Install TemplateGetting StartedFor an existing Scale Display from an old scanner:•Un

Strona 4 - Warranty

SITE PREPARATION AND INSTALLATION 3 - 15Installing1. Unpack the new Scale Display from its packaging.2. Place the proper Scale Display faceplate on th

Strona 5 - Revision History

3 - 16 MP6000 INTEGRATOR GUIDEInstall the Customer Side Scanner (MX101)The MX101 is an optional modular unit that fits into a modified MP6000 tower an

Strona 6

SITE PREPARATION AND INSTALLATION 3 - 17Installing the MX101 on the Customer’s Right Side (Default) of the Tower CoverTo install the MX101 on the cust

Strona 7 - TABLE OF CONTENTS

3 - 18 MP6000 INTEGRATOR GUIDE4. Remove the scan window cover from the CSS tower by squeezing the snaps shown below. The snaps are squeezed from insid

Strona 8

SITE PREPARATION AND INSTALLATION 3 - 196. Snap the scan window cover into place on the tower, over the CSS scan window.Figure 3-19 Snapping the Sc

Strona 9 - Table of Contents vii

3 - 20 MP6000 INTEGRATOR GUIDE8. Route the cable, looping through the right side cable slots as shown in Figure 3-21. (Cable wire should be tight.)Fig

Strona 10

SITE PREPARATION AND INSTALLATION 3 - 2110. Slide the CSS tower cover back into place. Ensure the cable service loop folds up into the blank space in

Strona 11 - Table of Contents ix

3 - 22 MP6000 INTEGRATOR GUIDE1. Push out the CSS blank side cover on the left side of the CSS tower cover, and replace the cover into the opening on

Strona 12

SITE PREPARATION AND INSTALLATION 3 - 236. Route the cable, looping through the left side cable slots as shown below.Figure 3-26 Routing the Cable7

Strona 13 - ABOUT THIS GUIDE

Table of Contents ixStatus Indicator Light ...

Strona 14 - Related Publications

3 - 24 MP6000 INTEGRATOR GUIDEAffix the label to the indentation under the MP6000 platter.Figure 3-28 Affix LabelInstall the MP6000 /ScaleEnsure al

Strona 15 - About This Guide vii

SITE PREPARATION AND INSTALLATION 3 - 25Cutout/Dimensions - MP6000 ShortFigure 3-29 MP6000 - Short Unit (No Scale) Counter CutoutFigure 3-30 MP6

Strona 16

3 - 26 MP6000 INTEGRATOR GUIDECutout/Dimensions - MP6000 Short (continued)Figure 3-31 MP6000 - Short Unit (No Scale) Top View DimensionsFigure 3-32

Strona 17 - FEATURES

SITE PREPARATION AND INSTALLATION 3 - 27Cutout/Dimensions - MP6000 MediumFigure 3-33 MP6000 - Medium Unit Counter CutoutFigure 3-34 MP6000 - Med

Strona 18 - Product Overview

3 - 28 MP6000 INTEGRATOR GUIDECutout/Dimensions - MP6000 Medium (continued)Figure 3-35 MP6000 - Medium Unit Side View DimensionsFigure 3-36 MP60

Strona 19 - Configurations

SITE PREPARATION AND INSTALLATION 3 - 29Cutout/Dimensions - MP6000 LongFigure 3-37 MP6000 - Long Unit Counter CutoutFigure 3-38 MP6000 - Long Un

Strona 20 - 1 - 4 MP6000 INTEGRATOR GUIDE

3 - 30 MP6000 INTEGRATOR GUIDECutout/Dimensions - MP6000 Long (continued)Figure 3-39 MP6000 - Long Unit Top View DimensionsTo install the MP6000:1.

Strona 21 - Table 1-1

SITE PREPARATION AND INSTALLATION 3 - 31b. To grasp the MP6000 to lower it into the checkstand, use the support handle on the back of the tower cover

Strona 22 - 1 - 6 MP6000 INTEGRATOR GUIDE

3 - 32 MP6000 INTEGRATOR GUIDEii. Medium MP6000 and short (shelf mount) MP6000: If the platter is not flush, or the MP6000 rocks, adjust the optional

Strona 23

SITE PREPARATION AND INSTALLATION 3 - 33Install Sensormatic CoilsThe horizontal antenna is installed below the platter, on the middle housing, affixed

Strona 24 - Peripherals

x MP6000 INTEGRATOR GUIDE

Strona 25 - Features of the MP6000

3 - 34 MP6000 INTEGRATOR GUIDE6. Secure each coil with two screws.7. Route the coil wires through the key hole on the side of the MP6000 for connectio

Strona 26 - Left Side View

SITE PREPARATION AND INSTALLATION 3 - 35Install Checkpoint AntennaThe Checkpoint EAS single axis wire loop antenna should be looped around the middle

Strona 27 - Leveling Screws

3 - 36 MP6000 INTEGRATOR GUIDETrim Kit Installation (If Required)The MX303-SR00004ZZWR trim kit can be used to modify the long MP6000/scale to fit int

Strona 28 - Figure 1-6

SITE PREPARATION AND INSTALLATION 3 - 37MP6000 Mounting Frame (If Required)Figure 3-47 Installing the Mounting Frame123

Strona 29 - Features Summary

3 - 38 MP6000 INTEGRATOR GUIDE

Strona 30

CHAPTER 4 SCALE CALIBRATION (MODELS WITH A SCALE ONLY)OverviewThis chapter describes how to calibrate the scale in the MP6000, and how to program its

Strona 31

4 - 2 MP6000 INTEGRATOR GUIDEScale Calibration Procedure (Scanner/Scale Configurations Only)Follow the steps below to calibrate the scale.Scale Config

Strona 32 - 2 - 2 MP6000 INTEGRATOR GUIDE

SCALE CALIBRATION (MODELS WITH A SCALE ONLY) 4 - 3Step 1 - Electronic Entry into Calibration ModeEncompasses all scales sold without a mechanical cali

Strona 33 - Programming Management Tools

4 - 4 MP6000 INTEGRATOR GUIDELegal Scale Dampening Filter Set the scale sensitivity to vibration by scanning the appropriate bar code (see page 4-17).

Strona 34 - Connecting a USB Interface

SCALE CALIBRATION (MODELS WITH A SCALE ONLY) 4 - 51. Depending on the units of measure programmed, place 25 lb or 11 kg on the scale. Ideally these we

Strona 35

ABOUT THIS GUIDEIntroductionThe MP6000 Integrator Guide provides information on installing, operating, and programming the MP6000.Chapter Descriptions

Strona 36 - USB Host Parameters

4 - 6 MP6000 INTEGRATOR GUIDEb. Place 11 kg weights on the scanner as shown in Figure 4-3; two 5 kg weights centered on the center of the scale, and o

Strona 37 - * IBM Table-top USB

SCALE CALIBRATION (MODELS WITH A SCALE ONLY) 4 - 7Step 5 - Calibration Success or FailureCalibration SuccessThe calibration process is successful if t

Strona 38 - USB Device Type (continued)

4 - 8 MP6000 INTEGRATOR GUIDE•Step 4 - Calibration at LOAD completes successfully, or unsuccessfully (fails).•A user scans Scale Reset (refer to the M

Strona 39

SCALE CALIBRATION (MODELS WITH A SCALE ONLY) 4 - 920.00 20.00 .01 lb .01 lb10.00 10.00 .01 lb .005 lb5.00 5.00 .005 lb .005 lb0.10 0.10 .005 lb .0025

Strona 40

4 - 10 MP6000 INTEGRATOR GUIDEThe weight checked at each position on the scale, shown in Figure 4-4, represent halfway between the center of the platt

Strona 41

SCALE CALIBRATION (MODELS WITH A SCALE ONLY) 4 - 11While performing a shift test, the indication of each position is within the applicable tolerance a

Strona 42 - Table 2-2

4 - 12 MP6000 INTEGRATOR GUIDEScale Configuration ParametersLegal Scale UnitsParameter # 995Scan a weight unit below to set the legal weight units for

Strona 43 - page 2-32

SCALE CALIBRATION (MODELS WITH A SCALE ONLY) 4 - 13Legal Scale Units (continued)Pounds(1)

Strona 44 - Connect MP6000 to RS-232 Host

4 - 14 MP6000 INTEGRATOR GUIDEScale Display ConfigurationParameter # 986Scan Enable Scale Display Configuration below to enable the Scale Display port

Strona 45 - RS-232 Parameters

SCALE CALIBRATION (MODELS WITH A SCALE ONLY) 4 - 15Scale Display Configuration (continued)* Disable Scale Display Configuration(0)

Strona 46 - RS-232 Host Parameters

vi MP6000 INTEGRATOR GUIDE•“User” refers to anyone operating the device.•“Device” refers to the MP6000.•Italics are used to highlight specific items i

Strona 47

4 - 16 MP6000 INTEGRATOR GUIDELegal Scale Dampening Filter SettingParameter # 996Scan a bar code below to set the vibration sensitivity of the scale.

Strona 48 - Table 2-7

SCALE CALIBRATION (MODELS WITH A SCALE ONLY) 4 - 17Parameter # 996 (continued)* Low Vibration Sensitivity(1)

Strona 49 - Table 2-8

4 - 18 MP6000 INTEGRATOR GUIDEParameter # 996 (continued)Very Low Vibration Sensitivity (2)

Strona 50 - RS-232 Host Types

SCALE CALIBRATION (MODELS WITH A SCALE ONLY) 4 - 19Parameter # 996 (continued)Ultra Low Vibration Sensitivity(3)

Strona 51 - *Standard RS-232

4 - 20 MP6000 INTEGRATOR GUIDEUser Interface Displays and SignalsTable 4-6 LEDs, and Beeper Sequences Scale State7-segment Diagnostic DisplayLED (S

Strona 52 - RS-232 Host Types (continued)

SCALE CALIBRATION (MODELS WITH A SCALE ONLY) 4 - 21Successfully entering scale legal Calibration Mode Step 2 - Program Legal Parameters and Step 3 - C

Strona 53

4 - 22 MP6000 INTEGRATOR GUIDESuccessfully executing and exiting a scale legal calibrationCalibration procedure semantics removed from display. No cha

Strona 54

CHAPTER 5 OPERATING THE SCANNEROverviewThis chapter describes how to operate the MP6000, including information about indicators (LEDs, beeper, etc,),

Strona 55

5 - 2 MP6000 INTEGRATOR GUIDEControls and IndicatorsSee Table 5-1 on page 5-20 for all beeper and LED indications.LED Array BarFigure 5-1 LED Array

Strona 56

OPERATING THE SCANNER 5 - 3Diagnostic LED/7-segment DisplayFigure 5-2 7-segment DisplayFigure 5-2 shows the internal 7-segment display which provid

Strona 57

About This Guide viiWhen contacting Motorola Solutions support, please have the following information available:•Serial number of the unit •Model numb

Strona 58

5 - 4 MP6000 INTEGRATOR GUIDEFront Panel ButtonsThe three front panel user interface buttons are backlit for ease of use.Scale Zero Button (Configurat

Strona 59

OPERATING THE SCANNER 5 - 5Sensormatic Manual Activation and Sensormatic Status ButtonFigure 5-5 EAS ButtonThis button indicates the state of the S

Strona 60 - RS-232 Host -NCR Variant

5 - 6 MP6000 INTEGRATOR GUIDEMP6000 Related HardwareScale Display (Scanner/Scale Configurations Only)MP6000 models with a scale have an option for a s

Strona 61

OPERATING THE SCANNER 5 - 7PlatterThe platter covers the horizontal scan window, and scale (if applicable). It also accommodates product placement. Th

Strona 62 - Parameter # 1246

5 - 8 MP6000 INTEGRATOR GUIDEInstalling/Removing the Long Scale PlatterThe long scale platter installs down into, and hooks onto the scale assembly.To

Strona 63

OPERATING THE SCANNER 5 - 9To remove the platter on a long MP6000 with a scale:1. Lift the rear of the platter slightly.2. Slide the platter backwards

Strona 64

5 - 10 MP6000 INTEGRATOR GUIDEOperating ModesThe MP6000 GEN I has two operating modes with corresponding power requirements (typical):•Idle Mode <

Strona 65

OPERATING THE SCANNER 5 - 11USB Staging Flash DriveA staging USB flash drive can be used to:a. Set up an MP6000 system from a 123Scan2 generated set o

Strona 66

5 - 12 MP6000 INTEGRATOR GUIDEManually Staging/Configuring MP6000 DevicesManually staging/configuring MP6000 devices using a USB flash drive is a thre

Strona 67 - Parameter # 1294

OPERATING THE SCANNER 5 - 13Loading Cloning FilesCloning files can be loaded to the staging flash drive two ways:•Insert the staging flash drive into

Strona 68 - Third Party Scale (continued)

viii MP6000 INTEGRATOR GUIDE

Strona 69 - Parameter # 1295

5 - 14 MP6000 INTEGRATOR GUIDE123Scan2 Staging Flash Drive ConfigurationThe Flash Drive Wizard option within the 123Scan2 utility steps a user through

Strona 70 - *Active High

OPERATING THE SCANNER 5 - 15ScanningThe MP6000 uses its horizontal and vertical scan windows simultaneously to provide a high swipe speed using six si

Strona 71 - Parameter # 1296

5 - 16 MP6000 INTEGRATOR GUIDEWeighing ItemsFor proper weighing, items should be placed fully on the shaded (gray) regions of the scanner.Figure 5-13

Strona 72

OPERATING THE SCANNER 5 - 17Electronic Article Surveillance (EAS)The MP6000 has integrated Electronic Article Surveillance (EAS) options which allow s

Strona 73

5 - 18 MP6000 INTEGRATOR GUIDEFor detailed information about these modes, and the parameter bar codes, refer to the MP6000 Bar Code Programming Guide.

Strona 74 - IBM RS-485 Host Parameters

OPERATING THE SCANNER 5 - 19Sensormatic EAS Soft Tags (Labels)Figure 5-16 Sensormatic EAS Soft Tags (Labels)Deactivation of soft tags alerts the us

Strona 75 - *None Selected

5 - 20 MP6000 INTEGRATOR GUIDEBeeper and LED ConditionsNOTE Refer to the MX101 Product Reference Guide (p/n 72E-171320-xx) for beeper and LED conditio

Strona 76

OPERATING THE SCANNER 5 - 21Press and hold Scale Zero button Click No change None If Scale Zero button is enabled, causes the scale calibration audit

Strona 77

5 - 22 MP6000 INTEGRATOR GUIDEFirmware DownloadFirmware DownloadLow, Medium, High beep after completeRed alternating between on and fast blinkNo chang

Strona 78

OPERATING THE SCANNER 5 - 23Macro PDF buffer flushed with no dataLow, High Beeps Red No change Flushing an already empty MPDF buffer.Scale: See Table

Strona 79

CHAPTER 1 PRODUCT OVERVIEW AND FEATURESIntroductionThis chapter includes the following topics:•Product Overview on page 1-2•Configurations on page 1-3

Strona 80

5 - 24 MP6000 INTEGRATOR GUIDEVolumePressed and release Volume/Tone buttonAnnunciates volume levelNo change Button LED blinks for two seconds (at 2 Hz

Strona 81

CHAPTER 6 123SCAN2Introduction123Scan² is an easy-to-use, PC-based software tool that enables the quick and easy setup of Motorola scanners.123Scan² u

Strona 82

6 - 2 MP6000 INTEGRATOR GUIDE123Scan2 Requirements•Host computer with Windows XP SP2 or Windows 7•Scanner•USB cable.For more information on123Scan², g

Strona 83 - Scale Display Port

APPENDIX A MAINTENANCE, TROUBLESHOOTING, AND ERROR CODESOverviewThis chapter provides error/warning codes, troubleshooting, and maintenance informati

Strona 84 - AUX A-B (Stacked USB)

A - 2 MP6000 INTEGRATOR GUIDETroubleshootingDiagnostic LED 7-segment Display - Error and Warning CodesThe MP6000 includes a one character LED display

Strona 85 - Table 2-16

MAINTENANCE, TROUBLESHOOTING, AND ERROR CODES A - 3Troubleshooting AssistanceIf an MP6000 displays any of the LED display codes preceded with an E the

Strona 86

A - 4 MP6000 INTEGRATOR GUIDEFigure A-3 UI Board and Top LED Board5. Replace all covers.6. Replace the platter on the unit.7. Remove any objects fr

Strona 87 - INSTALLATION

MAINTENANCE, TROUBLESHOOTING, AND ERROR CODES A - 5General Error and Warning CodesTable A-1 LED Display Error and Warning Codes LED Display CodeErr

Strona 88 - Site Preparation

A - 6 MP6000 INTEGRATOR GUIDEScale Warning CodesThe warning codes listed in Table A-2 display on the 7-segment display.Table A-2 Scale Fault Codes

Strona 89 - Grounding

MAINTENANCE, TROUBLESHOOTING, AND ERROR CODES A - 7U22Scale Communication Error This is a failed communication between the MP6000 scanner PCB and the

Strona 90 - Vertical Clearance

1 - 2 MP6000 INTEGRATOR GUIDEProduct OverviewThe MP6000 is a data capture solution that uses a sophisticated optical arrangement to view six sides of

Strona 91 - Ergonomics

A - 8 MP6000 INTEGRATOR GUIDE

Strona 92 - Installing Components

APPENDIX B TECHNICAL SPECIFICATIONSTechnical SpecificationsTable B-1 MP6000 Technical SpecificationsItem DescriptionPhysical CharacteristicsDimensi

Strona 93 - Unpacking MP6000 Equipment

B - 2 MP6000 INTEGRATOR GUIDEPower•12VDC from POS interface cable (USB PowerPlus, RS-232 or RS-485) •Motorola PWRS-14000-148R power supply: 90-264 VRM

Strona 94 - Pre-Installation Notes

TECHNICAL SPECIFICATIONS B - 3Imaging TechnologyType Multiple CMOS Array ImagerIllumination 640nm, controlled by item detection systemSides Read/Scan

Strona 95 - Required Tools

B - 4 MP6000 INTEGRATOR GUIDE

Strona 96

APPENDIX C HOST INTERFACE CHARACTER SETSIntroductionYou can assign the values in Table C-1 as prefixes or suffixes for ASCII character data transmissi

Strona 97 - Secure in Place

C - 2 MP6000 INTEGRATOR GUIDERS-232 Character SetsTable C-1 Character Sets Prefix/Suffix ValueFull ASCII Code 39 Encode CharacterRS-232 ASCII Chara

Strona 98 - Install the Scale Display

HOST INTERFACE CHARACTER SETS C - 31029 %C GS1030 %D RS1031 %E US1032 Space Space1033 /A !1034 /B1035 /C #1036 /D $1037 /E %1038 /F &1039 /G1040 /

Strona 99

C - 4 MP6000 INTEGRATOR GUIDE1060 %G <1061 %H =1062 %I >1063 %J ?1064 %V @1065 A A1066 B B1067 C C1068 D D1069 E E1070 F F1071 G G1072 H H1073 I

Strona 100 - Getting Started

HOST INTERFACE CHARACTER SETS C - 51091 %K [1092 %L \1093 %M ]1094 %N ^1095 %O _1096 %W1097 +A a1098 +B b1099 +C c1100 +D d1101 +E e1102 +F f1103 +G g

Strona 101 - Installing

PRODUCT OVERVIEW AND FEATURES 1 - 3ConfigurationsThe MP6000 captures printed or mobile 1D or 2D bar codes. An optional customer-side scanner (CSS) can

Strona 102

C - 6 MP6000 INTEGRATOR GUIDE1122 +Z z1123 %P {1124 %Q |1125 %R }1126 %S ~1127 (RS-232) Undefined7013 (RS-232 ENTERTable C-1 Character Sets (Contin

Strona 103

APPENDIX D PARAMETER DEFAULT TABLENOTE This guide includes limited parameter bar codes. For ALL MP6000 programming bar codes, refer to the MP6000 Bar

Strona 104

D - 2 MP6000 INTEGRATOR GUIDEDisable Scale Display4-15Legal Scale Dampening FilterLow Vibration Sensitivity4-17Table D-1 Parameter Defaults (Conti

Strona 105 - Connecting the USB Cable

INDEXNumerics0.0 connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1412V DC connector . . . . . . . . . . . . . . . . . . . . .

Strona 106

INDEX - 2 MP6000 INTEGRATOR GUIDEconfigurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3connectingIBM RS-485 interface . . .

Strona 107 - Figure 3-24

Index - 3scale display . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-12scanner/scale . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 108

INDEX - 4 MP6000 INTEGRATOR GUIDEconnection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4parameters . . . . . . . . . . . . . . . .

Strona 109

Thank you for your input—We value your comments.Tell Us What You Think...We’d like to know what you think about this Manual. Please take a moment to f

Strona 113 - Figure 3-34

1 - 4 MP6000 INTEGRATOR GUIDEMP6200-LN000M010NN Multi-plane scanner, long, with single interval scale, with Checkpoint, scale for OIML countries.MP620

Strona 114 - MX302-SR00004ZZWR

72E-172632-05 Revision A - July 2014Motorola Solutions, Inc.One Motorola PlazaHoltsville, New York 11742, USA1-800-927-9626http://www.motorolasolution

Strona 115 - Figure 3-38

PRODUCT OVERVIEW AND FEATURES 1 - 5MP6210-LN000M010CM Multi-plane scanner, long, single interval kg scale, with CSS, Checkpoint, Canada-Mexico scale l

Strona 116 - 506.9 mm

1 - 6 MP6000 INTEGRATOR GUIDEMP6210-MP000M010US Multi-plane scanner, medium, with single interval scale, with Checkpoint, with CSS, with DL parsing, s

Strona 117 - Figure 3-40

PRODUCT OVERVIEW AND FEATURES 1 - 7MP6510-MN000M010CM Multi-plane scanner, medium, with dual interval scale, with Checkpoint, with CSS, scale for Cana

Strona 118

1 - 8 MP6000 INTEGRATOR GUIDEPeripheralsThe MP6000 supports the peripheral devices listed below.Supported Auxiliary Hand-held ScannerThe MP6000 provid

Strona 119 - Install Sensormatic Coils

PRODUCT OVERVIEW AND FEATURES 1 - 9Features of the MP6000The following illustrations of the medium model show the features of the MP6000. See Table 1-

Strona 120

1 - 10 MP6000 INTEGRATOR GUIDEFigure 1-2 Left Side ViewFigure 1-3 Right Side View/Connector PortsScale Cable Channel EAS Cable Channel (also see

Strona 121 - Install Checkpoint Antenna

PRODUCT OVERVIEW AND FEATURES 1 - 11Figure 1-4 View Under PlatterFigure 1-5 Leveling ScrewsOptional Scale (scale is not available in MP6000 shor

Strona 122 - Figure 3-46

1 - 12 MP6000 INTEGRATOR GUIDEFigure 1-6 Scale Displays (Some Scanner/Scale Configurations Only) - Single Head (MX201) and Dual Head (MX202; additi

Strona 123 - Installing the Mounting Frame

PRODUCT OVERVIEW AND FEATURES 1 - 13Features SummaryTable 1-2 Features on the MP6000 Feature Description PageDiagnostic LED/7-segment DisplayIntern

Strona 124

MP6000 INTEGRATOR GUIDE72E-172632-05Revision A July 2014

Strona 125 - WITH A SCALE ONLY)

1 - 14 MP6000 INTEGRATOR GUIDETable 1-3 Description of ConnectorsPort DescriptionRS-232 AUX 1 (J7) See Table 2-3 on page 2-13 for description.0.0 (

Strona 126 - Scale Configurations

CHAPTER 2 HOST INTERFACES AND CABLE PINOUTSOverviewThis chapter describes the host interfaces supported by the MP6000, and how to connect the MP6000 t

Strona 127 - Important Notes

2 - 2 MP6000 INTEGRATOR GUIDEInterfaces, Components, and CommunicationThe MP6000 supports the following.POS Interfaces and Host Communication•USB 2.0

Strona 128 - Legal Scale Dampening Filter

HOST INTERFACES AND CABLE PINOUTS 2 - 3Programming Management Tools•123Scan2 (see Chapter 6, 123SCAN2)•SMS•Staging flash drive reprogramming (USB memo

Strona 129

2 - 4 MP6000 INTEGRATOR GUIDEConnecting a USB InterfaceThe MP6000 connects directly to a USB host. An additional power supply may be required (PWRS-14

Strona 130 - 4 - 6 MP6000 INTEGRATOR GUIDE

HOST INTERFACES AND CABLE PINOUTS 2 - 5To set up the MP6000:1. Connect the RJ-45 modular connector of the USB interface cable to the POS interface por

Strona 131 - Calibration Failure

2 - 6 MP6000 INTEGRATOR GUIDEUSB Host ParametersUSB Device TypeTo select a USB device type, scan one of the bar codes listed in Table 2-1.NOTE 1.When

Strona 132 - Verification Test

HOST INTERFACES AND CABLE PINOUTS 2 - 7USB Device Type (continued)* IBM Table-top USB

Strona 133 - Table 4-4

2 - 8 MP6000 INTEGRATOR GUIDEUSB Device Type (continued)IBM Hand-held USB

Strona 134

HOST INTERFACES AND CABLE PINOUTS 2 - 9USB Device Type (continued)IBM OPOS(IBM Hand-held USB with Full Scan Disable)

Strona 135 - Audit Tallies

ii MP6000 INTEGRATOR GUIDE© 2013-2014 Motorola Solutions, Inc. All rights reserved.No part of this publication may be reproduced or used in any form,

Strona 136 - * Kilograms

2 - 10 MP6000 INTEGRATOR GUIDEUSB Device Type (continued)HID Keyboard EmulationWhen the HID Keyboard host is selected, and the MP6000 has auxiliary sc

Strona 137 - Legal Scale Units (continued)

HOST INTERFACES AND CABLE PINOUTS 2 - 11USB Device Type (continued)CDC COM Port Emulation

Strona 138 - Parameter # 986

2 - 12 MP6000 INTEGRATOR GUIDEConnecting an RS-232 InterfaceMP6000 Scanner Only or MP6200/6500 Scale with Single Cable ProtocolUse the RS-232 interfac

Strona 139

HOST INTERFACES AND CABLE PINOUTS 2 - 13Price Computational Scale Interface Circuit DrawingPrice Computational Scale Interface available on AUX 1. (Al

Strona 140 - Parameter # 996

2 - 14 MP6000 INTEGRATOR GUIDEConnect MP6000 to RS-232 HostTo connect the MP6000 to an RS-232 host:1. Connect the modular connector of the RS-232 inte

Strona 141 - * Low Vibration Sensitivity

HOST INTERFACES AND CABLE PINOUTS 2 - 15RS-232 ParametersNOTE This guide includes limited parameter bar codes. For ALL MP6000 programming bar codes, r

Strona 142 - Parameter # 996 (continued)

2 - 16 MP6000 INTEGRATOR GUIDERS-232 Host ParametersVarious RS-232 hosts use their own parameter default settings. Selecting standard, ICL, Fujitsu, W

Strona 143

HOST INTERFACES AND CABLE PINOUTS 2 - 17RS-232 Host Parameters (continued)Table 2-6 Terminal Specific RS-232 Parameter Olivetti Omron CUTENCR(Sing

Strona 144 - Table 4-6

2 - 18 MP6000 INTEGRATOR GUIDERS-232 Host Parameters (continued)Selecting ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olive

Strona 145

HOST INTERFACES AND CABLE PINOUTS 2 - 19Table 2-8 Terminal Specific Code ID Characters Code Type Olivetti Omron CUTE NCR DatalogicUPC-A A A AA AUP

Strona 146

iiiRevision HistoryChanges to the original guide are listed below:Change Date Description-01 Rev A 6/2013 Initial Release.-02 Rev A 6/2013 Added:- Fi

Strona 147 - Overview

2 - 20 MP6000 INTEGRATOR GUIDERS-232 Host TypesTo select an RS-232 host interface, scan one of the following bar codes.Options:•Standard RS-232 (defau

Strona 148 - Controls and Indicators

HOST INTERFACES AND CABLE PINOUTS 2 - 21RS-232 Host Types (continued)*Standard RS-232

Strona 149 - OPERATING THE SCANNER 5 - 3

2 - 22 MP6000 INTEGRATOR GUIDERS-232 Host Types (continued)ICL RS-232

Strona 150 - Volume/Tone Control Button

HOST INTERFACES AND CABLE PINOUTS 2 - 23RS-232 Host Types (continued)Wincor-Nixdorf RS-232 Mode A

Strona 151 - Soft Reset Buttons

2 - 24 MP6000 INTEGRATOR GUIDERS-232 Host Types (continued)Wincor-Nixdorf RS-232 Mode B

Strona 152 - Dual Interval Range Scales

HOST INTERFACES AND CABLE PINOUTS 2 - 25RS-232 Host Types (continued)Olivetti ORS4500

Strona 153 - OPERATING THE SCANNER 5 - 7

2 - 26 MP6000 INTEGRATOR GUIDERS-232 Host Types (continued)Omron

Strona 154 - 5 - 8 MP6000 INTEGRATOR GUIDE

HOST INTERFACES AND CABLE PINOUTS 2 - 27RS-232 Host Types (continued)OPOS/JPOS

Strona 155 - Scan Windows

2 - 28 MP6000 INTEGRATOR GUIDERS-232 Host Types (continued)Fujitsu RS-232

Strona 156 - Programming the MP6000

HOST INTERFACES AND CABLE PINOUTS 2 - 29RS-232 Host Types (continued)CUTE 2

Strona 157 - USB Staging Flash Drive

iv MP6000 INTEGRATOR GUIDE

Strona 158 - Flash DrivesFlash Drives

2 - 30 MP6000 INTEGRATOR GUIDERS-232 Host Types (continued)RS-232 Host -NCR VariantScan the bar code below to enable the NCR variant of the RS-232 hos

Strona 159 - Loading Cloning Files

HOST INTERFACES AND CABLE PINOUTS 2 - 31RS-232 Host Types (continued)RS-232 Host -Datalogic VariantScan the bar code below to enable the Datalogic var

Strona 160

2 - 32 MP6000 INTEGRATOR GUIDERS-232 Device Port Configuration Parameter # 1246This option allows the user to select which devices to attach to the MP

Strona 161 - Scanning

HOST INTERFACES AND CABLE PINOUTS 2 - 33RS-232 Device Port Configuration (continued)*AUX 1 Sensormatic and AUX 2 RS-232 Scanner(00h)

Strona 162 - Weighing Items

2 - 34 MP6000 INTEGRATOR GUIDERS-232 Device Port Configuration (continued)AUX 1 Dual Cable Scale and AUX 2 RS-232 Scanner(01h)

Strona 163 - Supported EAS Controllers

HOST INTERFACES AND CABLE PINOUTS 2 - 35RS-232 Device Port Configuration (continued)AUX 1 Sensormatic and AUX 2 Dual Cable Scale(02h)

Strona 164 - Sensormatic EAS Hard Tags

2 - 36 MP6000 INTEGRATOR GUIDERS-232 Device Port Configuration (continued)AUX 1 Third Party Scale, AUX 2 Sensormatic(04h)

Strona 165 - OPERATING THE SCANNER 5 - 19

HOST INTERFACES AND CABLE PINOUTS 2 - 37Third Party Scale ParametersThird Party ScaleParameter # 1294Enable or disable Third Party Scale functionality

Strona 166 - Beeper and LED Conditions

2 - 38 MP6000 INTEGRATOR GUIDEThird Party Scale (continued)* Disable Third Party Scale(0)

Strona 167 - OPERATING THE SCANNER 5 - 21

HOST INTERFACES AND CABLE PINOUTS 2 - 39Third Party Scale LED PinParameter # 1295This parameter defines the polarity of the LED/Tare input pin that il

Strona 168 - Table 5-1

Warranty ... ii

Strona 169 - OPERATING THE SCANNER 5 - 23

2 - 40 MP6000 INTEGRATOR GUIDEThird Party Scale LED Pin (continued)*Active High(1)

Strona 170

HOST INTERFACES AND CABLE PINOUTS 2 - 41Third Party Scale Zero PinParameter # 1296This parameter defines the polarity of the zero output pin when the

Strona 171 - CHAPTER 6 123SCAN2

2 - 42 MP6000 INTEGRATOR GUIDEThird Party Scale Zero Pin (continued)*Active High(1)

Strona 172 - Requirements

HOST INTERFACES AND CABLE PINOUTS 2 - 43Connecting an IBM RS-485 InterfaceConnect the MP6000 directly to the host interface.Figure 2-4 IBM RS-485 C

Strona 173 - ERROR CODES

2 - 44 MP6000 INTEGRATOR GUIDEIBM RS-485 Host ParametersTo select the IBM RS-485 port used, scan one of the bar codes listed in Table 2-9..IMPORTANT T

Strona 174 - Troubleshooting

HOST INTERFACES AND CABLE PINOUTS 2 - 45IBM Port Addresses*None Selected

Strona 175 - Troubleshooting Assistance

2 - 46 MP6000 INTEGRATOR GUIDEIBM Port Addresses (continued)Hand-held Scanner Emulation (Port 9B)

Strona 176 - A - 4 MP6000 INTEGRATOR GUIDE

HOST INTERFACES AND CABLE PINOUTS 2 - 47IBM Port Addresses (continued)Non-IBM Scanner Emulation (Port 5B)

Strona 177 - Table A-1

2 - 48 MP6000 INTEGRATOR GUIDEIBM Port Addresses (continued)Tabletop Scanner Emulation (Port 17)

Strona 178 - Scale Warning Codes

HOST INTERFACES AND CABLE PINOUTS 2 - 49IBM Scale Port AddressesThe scale port address must be configured for the scale to operate on the IBM RS-485 b

Strona 179

vi MP6000 INTEGRATOR GUIDEUSB Host Parameters ...

Strona 180 - A - 8 MP6000 INTEGRATOR GUIDE

2 - 50 MP6000 INTEGRATOR GUIDEIBM Scale Port Addresses (continued)Port 6A

Strona 181 - Technical Specifications

HOST INTERFACES AND CABLE PINOUTS 2 - 51IBM Scale Port Addresses (continued)Port 6B

Strona 182 - B - 2 MP6000 INTEGRATOR GUIDE

2 - 52 MP6000 INTEGRATOR GUIDEIBM Scale Port Addresses (continued)Port 6E

Strona 183 - Table B-1

HOST INTERFACES AND CABLE PINOUTS 2 - 53Connector PinsRS-232 AUX 1Scale Display PortTable 2-10 RJ-45Pin # Signal/Name Direction Description1 N/C N/

Strona 184 - B - 4 MP6000 INTEGRATOR GUIDE

2 - 54 MP6000 INTEGRATOR GUIDERS-232 AUX 2Checkpoint InterlockAUX A-B (Stacked USB)Table 2-12 RJ-45Pin # Signal/Name Direction Description1 N/C N/A

Strona 185 - CHARACTER SETS

HOST INTERFACES AND CABLE PINOUTS 2 - 55POS12V DC NOTE An additional USB port is available in the front under the platter. All USB ports can be used f

Strona 186 - RS-232 Character Sets

2 - 56 MP6000 INTEGRATOR GUIDE

Strona 187 - Table C-1

CHAPTER 3 SITE PREPARATION AND INSTALLATIONOverviewThe MP6000 was designed to drop into an existing bioptic checkstand cutout with no modifications. T

Strona 188 - C - 4 MP6000 INTEGRATOR GUIDE

3 - 2 MP6000 INTEGRATOR GUIDESite PreparationVentilation and Spacing RequirementsThe scanner/scale housing was designed to provide adequate space for

Strona 189

SITE PREPARATION AND INSTALLATION 3 - 3Electrical Power ConsiderationsThe MP6000 may be powered from two different sources:•POS Equipment• IBM registe

Strona 190 - C - 6 MP6000 INTEGRATOR GUIDE

Table of Contents viiGetting Started ...

Strona 191 - Table D-1

3 - 4 MP6000 INTEGRATOR GUIDECheckstand PreparationIf the MP6000 is not replacing an old bioptic device, and you are installing for the first time int

Strona 192 - D - 2 MP6000 INTEGRATOR GUIDE

SITE PREPARATION AND INSTALLATION 3 - 5Counter CutoutThere are three different MP6000 models: long, medium, and short. Prior to cutting the counter op

Strona 193 - Numerics

3 - 6 MP6000 INTEGRATOR GUIDEInstalling ComponentsThe MP6000 can be installed with or without the following options:•Scale and Scale Display (dependin

Strona 194

SITE PREPARATION AND INSTALLATION 3 - 7Remove Existing Bioptic Scanner and AccessoriesIf you are replacing existing equipment, follow these step to re

Strona 195 - Index - 3

3 - 8 MP6000 INTEGRATOR GUIDE2. For added protection during shipment, the MP6000 platter is covered with a tight fitting layer of plastic as shown in

Strona 196

SITE PREPARATION AND INSTALLATION 3 - 9Assemble the Dual Head Scale DisplayRequired Tools •Phillips head screw driver.To convert a single display to a

Strona 197 - Tell Us What You Think

3 - 10 MP6000 INTEGRATOR GUIDE4. Remove the circular cap from the existing display and either discard, or keep it as a spare part.Figure 3-7 Removi

Strona 198

SITE PREPARATION AND INSTALLATION 3 - 117. Secure in place using the pole grip and two M3 x 12 self tapping screws supplied. These are Phillips screw

Strona 199

3 - 12 MP6000 INTEGRATOR GUIDEInstall the Scale DisplayWhen installing the optional Scale Display, consider both the cashier and customer’s viewing an

Strona 200

SITE PREPARATION AND INSTALLATION 3 - 13Figure 3-12 Dual Scale Display - Dimensions; Display Rotates Independently (Approximately 290 o) 2.8 in70.0