4-8
LS 1004 Product Reference Guide
enabled. To do this, scan the DECODE UPC ONLY ENABLE bar code. Youll hear hi/lo/hi/
low warble. The warble sound indicates that the scanner has been successfully programmed
for the selected parameter. Other beeper indications are listed in Chapter 3.
The default for INTERCHARACTER DELAY is 0 msec, but you need it set to 2 msec. To
program the scanner for a 2msec intercharacter delay, scan the bar codes listed below. This
sequence includes a two-digit entry; single-digit entries require a leading zero.
Youll hear...
1. Scan INTERCHARACTER DELAY Short high tone
2. Scan 0 Short high tone
3. Scan 2 Hi/Lo/Hi/Lo warble
Errors While Scanning
Dont worry if you make an error during a scanning sequence. If youre scanning a multi-step
sequence, scanning CANCEL removes you from that sequence so that you can start again.
Otherwise, simply scan the single correct bar code for the desired parameter.