Motorola Canopy Backhaul Module Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Networking Motorola Canopy Backhaul Module. Motorola Canopy Backhaul Module Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - USER MANUA L

Canopy TM Backhaul ModuleUSER MANUA LBH02-UM-enIssue 3October 2003© 2003 Motorola, Inc. All rights reserved. Printed in the U.S.A

Strona 2

Backhaul User Manual Issue 3 Page 10 of 53Remove the base cover as shown in FIGURE 1 to access the Ethernet connection and theConnection LED alignme

Strona 3 - Exposure Note

Backhaul User Manual Issue 3 Page 11 of 53PWR: The power LED displays the status of power to the module. The LED will be constantly lit ifpower is

Strona 4 - Hardware Warranty in U.S

Backhaul User Manual Issue 3 Page 12 of 53BACKGROUND INFORMATION ON NETWORKINGComputers are assigned IP addresses by network operators, which have t

Strona 5

Backhaul User Manual Issue 3 Page 13 of 53SYSTEM OVERVIEW AND SITE PLANNINGDefinitions:Backhaul Timing Master – a module that is used in a point-to-

Strona 6

Backhaul User Manual Issue 3 Page 14 of 53CanopyBackhaulSlavesCanopyBackhaulMasterCanopyBackhaulMasterCMM CMMExample 3: The multiple hop with the b

Strona 7

Backhaul User Manual Issue 3 Page 15 of 53interfere with the signal? Will trees grow into the line-of-sight path?• When possible, avoid high RF en

Strona 8 - GETTING STARTED

Backhaul User Manual Issue 3 Page 16 of 53General Considerations• Fresnel Loss - The Fresnel Zone is a theoretical area around the line of sight of

Strona 9 - PRODUCT DESCRIPTION

Backhaul User Manual Issue 3 Page 17 of 53Channel PlansWhether using 5.2 GHz or 5.7 GHz modules, frequencies should never be placed closerthan 20 MH

Strona 10 - Operational Mode

Backhaul User Manual Issue 3 Page 18 of 53Networking InformationThe Canopy access point module will each use an IP address on the operator’s network

Strona 11 - Alignment Mode

Backhaul User Manual Issue 3 Page 19 of 53Reflector dishesThe passive reflector arm is molded to receive the plastic housing of the backhaul module.

Strona 12

Backhaul User Manual Issue 3 Page 2 of 53NOTICESImportant Note on ModificationsIntentional or unintentional changes or modifications to the equipmen

Strona 13

Backhaul User Manual Issue 3 Page 20 of 53ADVANCED FEATURESThese features may be used in the Canopy System but are not required for basic operation.

Strona 14 - Site Selection Criteria

Backhaul User Manual Issue 3 Page 21 of 53is not enabled, AES modules can communicate with DES modules.BrandingOn each Canopy module, the web-based

Strona 15

Backhaul User Manual Issue 3 Page 22 of 53specific information on this MIB see RFC 1213 for details.

Strona 16 - Transmitter Receiver

Backhaul User Manual Issue 3 Page 23 of 53INSTALLATIONThe following steps are required to install the Canopy backhaul module:• Unpack the Canopy pr

Strona 17 - Channel Plans

Backhaul User Manual Issue 3 Page 24 of 53module so that it can register with a backhaul timing master module. The color codes mustmatch.The operat

Strona 18 - Specification

Backhaul User Manual Issue 3 Page 25 of 53• Replace the base cover on all of the backhaul modules.Alignment• If the backhaul modules are not utili

Strona 19 - Reflector dish arm

Backhaul User Manual Issue 3 Page 26 of 53CABLINGIt is strongly recommended to use shielded cable for all Canopy infrastructure cabling associatedwi

Strona 20 - ADVANCED FEATURES

Backhaul User Manual Issue 3 Page 27 of 53RJ-45 Crossover: pin 1 → white / orange ← pin 3 pin 2 → orange ← pin 6 pin 3 → whit

Strona 21 - Branding

THE INTERFACE SCREENSThe Canopy backhaul module contains a series of web pages that are used to interface to the unit.The following is a quick referen

Strona 22 - RFC 1213

THE TIMING MASTERQuick StartThe Canopy System consists of a family of highly flexible, fixed wireless access devices that canbe put into service quick

Strona 23 - INSTALLATION

Backhaul User Manual Issue 3 Page 3 of 53Backhaul withReflector5.725 to 5.825GHz200mW RMS 63 Watts EIRP High Index 2-levelor 4-level FSK5745 to 5805

Strona 24 - Installation of the equipment

Status PageThe Status page contains information on the operation of the product. It is the default web page.The following parameters are displayed:De

Strona 25 - RSSI Only mode

• ERROR: No Sync Pulse: If the module is set to receive a sync pulse from an outsidesource (not itself) and it is currently not receiving the pulse

Strona 26

ConfigurationThe Configuration web page contains information and configurable parameters pertaining to theoperation of the product. The first line of

Strona 27

LAN 1 IP: enter in the IP address that will be associated with the Ethernet connection on thismodule. The default address is 169.254.1.1. If the I

Strona 28 - THE INTERFACE SCREENS

when used, will allow view and change activities to the module. When the full-access password isset, the password will also be tied to telnet and FTP

Strona 29 - THE TIMING MASTER

management server. The buffer size for this field is 128 characters.Site Contact: enter contact information relating to the module. This paramete

Strona 30 - Receiving Sync

Event LogThis page contains information that is recorded from the subscriber module for troubleshootingpurposes. Please make note of the information

Strona 31 - Configuration

Link TestThe Link Test is a test for measuring the throughput and efficiency of the RF link between twoCanopy modules.To perform a link test enter a n

Strona 32 - Device Type

SessionsThe Session web page contains information on each of the subscriber modules that has registeredto the access point module. For each of the s

Strona 33 - AP Eval Data

Average Jitter: displays the average Jitter value for the subscriber module.Last Jitter: displays the last Jitter value for the subscriber module.GP

Strona 34

Backhaul User Manual Issue 3 Page 4 of 53LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ANDNONINFRINGEMENT.

Strona 35 - Canopy Default Plug

EthBusErr: displays the total number of Ethernet bus errors on the Ethernet controller.CRCError: displays the total number of CRC errors on the Ethe

Strona 36 - LUID Select

THE TIMING SLAVEStatusThe Status page contains information on the operation of the product. It is the default web page.The following parameters are d

Strona 37 - Set Time and Date

an access point module.• Syncing – module is attempting to synchronize timing to a single access point module• Registering – module sent a request for

Strona 38 - IN SESSION:

Configuration PageThe Configuration web page contains information and configurable parameters pertaining to theoperation of the product. The first li

Strona 39 - Ethernet Stats

Default Gateway: enter in an appropriate gateway address for the module. The default value forthis parameter is 169.254.0.0.Color Code: enter in a

Strona 40 - Expanded Stats

SNMP management server. The buffer size for this field is 256 characters.Save Changes: by clicking on this button, any changes that have been made o

Strona 41 - Scanning

Out of Range: displays a counter for the number of times the access point module has seen asubscriber module who has attempted to register and has be

Strona 42 - Alignment

Link TestThe Link Test is a test for measuring the throughput and efficiency of the RF link between twoCanopy modules.To perform a link test enter a n

Strona 43

AlignmentThe Alignment web page contains tools to assist in the alignment of a subscriber module to anaccess point module. There are two modes that c

Strona 44

any one of these criteria are not met the link may still be operational but may have issues time totime.Note: If a Canopy module is placed into Alig

Strona 45 - Index: 5”

Backhaul User Manual Issue 3 Page 5 of 53GENERAL, SPECIAL, INCIDENTAL, CONSEQUENTIAL, EXEMPLARY OR OTHER DAMAGE ARISING OUT OF THE USEOR INABILITY T

Strona 46

ACCESSORIESThe following accessories are available for use with the Canopy System. To purchaseaccessories, please contact an authorized Canopy dealer

Strona 47 - Link Test

APPENDIXThere are two basic concepts that are needed for a basic understanding of networking, IPaddresses and subnet masks. IP addresses are 32-bit

Strona 48

SPECIFICATIONSOperating FrequencyRangeU-NII: 5.25 to 5.35 GHz and 5.725 to 5.825 GHzISM: 5.725 to 5.850 GHzAccess Method Time Division Multiple Access

Strona 49 - BER Display

with passive reflector 6.5 lbs. (3 kg)

Strona 50 - ACCESSORIES

Backhaul User Manual Issue 3 Page 6 of 53TABLE OF CONTENTSGETTING STARTED ...

Strona 51 - APPENDIX

Backhaul User Manual Issue 3 Page 7 of 53Status...

Strona 52 - SPECIFICATIONS

Backhaul User Manual Issue 3 Page 8 of 53GETTING STARTEDWELCOMEThank you for your purchase of a Motorola Canopy Backhaul module. This new technology

Strona 53

Backhaul User Manual Issue 3 Page 9 of 53PRODUCT DESCRIPTIONCanopy BackhaulBackhaul links provide point-to-point connectivity either as a standalone

Komentarze do niniejszej Instrukcji

Brak uwag