Motorola LD-W-1 Dokumentacja Strona 27

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 36
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 26
LD-G-1 / LD-W-1 English
Page 55
!
FAQ
§ Parts are getting too hot and/or start to smoke.
Disconnect the system from the mains immediately!
Possible cause: one or more connections are soldered incorrectly.
à Check the connections.
Possible cause: The connection of the motor is connected to locomotive
ground. à Disconnect the connection from locomotive ground.
§ A lamp flickers (this is not a defect).
Possible cause: The lamp is connected with one side to locomotive
ground. à If you do not want the lamp to flicker, disconnect it from
locomotive ground, insulate it and connect it to the return
conductor (point X1).
§ The locomotive runs too slowly or too fast.
Possible cause: Different locomotives react in different ways to
identical programmings. à Adapt the programming to the
individual characteristics of the locomotive.
§ The locomotive does not react to F4.
Possible cause: Instead of Motorola II format, Motorola I format is
set at the central unit. à Set Motorola II format.
If you cannot find the problem, please return the decoder for repair
(address on the cover page).
Manufacturer's note
According to DIN VDE 0869, the person who brings the circuit into
operation by extension resp. mounting into a housing is the
manufacturer of the product. If he sells the product to another person
he is responsible for passing on all the relevant papers and to give his
name and address.
Przeglądanie stron 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 35 36

Komentarze do niniejszej Instrukcji

Brak uwag