Motorola Phaser P460 Instrukcje Operacyjne

Przeglądaj online lub pobierz Instrukcje Operacyjne dla Czytniki kodów kreskowych Motorola Phaser P460. Motorola Phaser P460 Operating instructions Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Product Reference Guide

P460/P360 MemoryScannersProduct Reference Guide

Strona 2 - P460/P360 Memory Scanners

ixAbout This ManualIntroductionThe P460/P360 Memory Scanner Product Reference Guide provides general instructions for setup, operation, troubleshootin

Strona 3

5-41Parameter MenusEAN Zero ExtendIf this parameter is enabled, five leading zeros are added to decoded EAN-8 symbols to make them compatible in forma

Strona 4 - Contents

5-42P460/P360 Memory Scanners Product Reference GuideConvert EAN-8 to EAN-13 TypeWhen EAN Zero Extend is enabled, this parameter gives you the option

Strona 5 - Chapter 3. Operation

5-43Parameter MenusUPC/EAN Coupon CodeWhen this parameter is enabled, the Phaser decodes UPC-A, UPC-A with 2 supplemental characters, UPC-A with 5 sup

Strona 6 - Chapter 5. Parameter Menus

5-44P460/P360 Memory Scanners Product Reference GuideEnable/Disable Code 128Scan the appropriate bar code below to enable or disable Code 128.ENABLE C

Strona 7

5-45Parameter MenusEnable/Disable UCC/EAN-128Scan the appropriate bar code below to enable or disable UCC/EAN-128. (See Appendix A, Bar Code Informati

Strona 8

5-46P460/P360 Memory Scanners Product Reference GuideEnable/Disable ISBT 128 (2D Scanner only)To enable or disable ISBT 128, scan the appropriate bar

Strona 9 - Feedback

5-47Parameter MenusEnable/Disable Code 39Scan the appropriate bar code below to enable or disable Code 39.ENABLE CODE 39DISABLE CODE 39

Strona 10 - About This Manual

5-48P460/P360 Memory Scanners Product Reference GuideEnable/Disable Trioptic Code 39Trioptic Code 39 symbols always contain six characters. Trioptic C

Strona 11 - Service Information

5-49Parameter MenusSet Lengths for Code 39Lengths for Code 39 may be set for any length, one or two discrete lengths, or lengths within a specific ran

Strona 12 - Symbol Support Center

5-50P460/P360 Memory Scanners Product Reference GuideSet Lengths for Code 39 (Continued)Length Within Range - This option allows you to decode a code

Strona 13

xP460/P360 Memory Scanners Product Reference Guide" lists of alternatives" lists of required steps that are not necessarily sequential!Seque

Strona 14 - Warranty

5-51Parameter MenusCode 39 Check Digit VerificationWhen enabled, this parameter checks the integrity of a Code 39 symbol to ensure it complies with sp

Strona 15

5-52P460/P360 Memory Scanners Product Reference GuideTransmit Code 39 Check DigitScan the appropriate bar code below to transmit the data with or with

Strona 16 - The Phaser Series Scanner

5-53Parameter MenusEnable/Disable Code 39 Full ASCIIScan the appropriate bar code below to enable or disable Code 39 Full ASCII.When enabled, the ASCI

Strona 17 - The Cradle

5-54P460/P360 Memory Scanners Product Reference GuideConvert Code 39 to Code 32Scan the appropriate bar code below to enable or disable converting Cod

Strona 18

5-55Parameter MenusCode 32 PrefixScan the appropriate bar code below to enable or disable the prefix character “A” to all Code 32 bar codes.Note:Conve

Strona 19

5-56P460/P360 Memory Scanners Product Reference GuideEnable/Disable Code 93Scan the appropriate bar code below to enable or disable Code 93.ENABLE COD

Strona 20 - Chapter 2

5-57Parameter MenusSet Lengths for Code 93Lengths for Code 93 may be set for any length, one or two discrete lengths, or lengths within a specific ran

Strona 21

5-58P460/P360 Memory Scanners Product Reference GuideSet Lengths for Code 93 (Continued)Length Within Range - This option allows you to decode a code

Strona 22 - Setting Up the Cradle

5-59Parameter MenusEnable/Disable Interleaved 2 of 5Scan the appropriate bar code below to enable or disable Interleaved 2 of 5.ENABLE INTERLEAVED 2 O

Strona 23 - Charging the Battery

5-60P460/P360 Memory Scanners Product Reference GuideSet Lengths for Interleaved 2 of 5 Lengths for I 2 of 5 may be set for any length, one or two dis

Strona 24 - Connecting to a Host

xiAbout This ManualSymbol Support CenterFor service information, warranty information or technical assistance contact or call the Symbol Support Cente

Strona 25 - To Cradle

5-61Parameter MenusSet Lengths for Interleaved 2 of 5 (Continued)Length Within Range - This option allows you to decode a code type within a specified

Strona 26

5-62P460/P360 Memory Scanners Product Reference GuideI 2 of 5 Check Digit VerificationWhen enabled, this parameter checks the integrity of an I 2 of 5

Strona 27

5-63Parameter MenusTransmit I 2 of 5 Check DigitScan the appropriate bar code below to transmit the data with or without the check digit.TRANSMIT I 2

Strona 28 - Operation

5-64P460/P360 Memory Scanners Product Reference GuideConvert I 2 of 5 to EAN-13This parameter converts a 14 character I 2 of 5 code into EAN-13, and t

Strona 29 - Batch / Inventory Application

5-65Parameter MenusEnable/Disable Discrete 2 of 5Scan the appropriate bar code below to enable or disable Discrete 2 of 5.ENABLE DISCRETE 2 OF 5DISABL

Strona 30 - Alpha Data Entry

5-66P460/P360 Memory Scanners Product Reference GuideSet Lengths for Discrete 2 of 5 Lengths for D 2 of 5 may be set for any length, one or two discre

Strona 31 - aaaa/bbbb

5-67Parameter MenusSet Lengths for Discrete 2 of 5 (Continued)Length Within Range - This option allows you to decode a code type within a specified ra

Strona 32 - Transmitting Data to the Host

5-68P460/P360 Memory Scanners Product Reference GuideEnable/Disable CodabarScan the appropriate bar code below to enable or disable Codabar.ENABLE COD

Strona 33 - Scan and Transmit Application

5-69Parameter MenusSet Lengths for CodabarLengths for Codabar may be set for any length, one or two discrete lengths, or lengths within a specific ran

Strona 34 - System Menu

5-70P460/P360 Memory Scanners Product Reference GuideSet Lengths for Codabar (Continued)Length Within Range - This option allows you to decode a code

Strona 35 - System Setup

xiiP460/P360 Memory Scanners Product Reference GuideFinlandOy Symbol TechnologiesKaupintie 8 A 6FIN-00440 Helsinki, Finland9 5407 580 (Inside Finland)

Strona 36 - App. Control

5-71Parameter MenusCLSI EditingIf enabled, this parameter strips the start and stop characters and inserts a space after the first, fifth, and tenth c

Strona 37

5-72P460/P360 Memory Scanners Product Reference GuideNOTIS EditingIf enabled, this parameter strips the start and stop characters from a decoded Codab

Strona 38

5-73Parameter MenusEnable/Disable MSI PlesseyScan the appropriate bar code below to enable or disable MSI Plessey.ENABLE MSI PLESSEYDISABLE MSI PLESSE

Strona 39 - System Status

5-74P460/P360 Memory Scanners Product Reference GuideSet Lengths for MSI Plessey Lengths for MSI Plessey may be set for any length, one or two discret

Strona 40 - ADF Plus

5-75Parameter MenusSet Lengths for MSI Plessey (Continued)Length Within Range - This option allows you to decode a code type within a specified range.

Strona 41 - Scanning

5-76P460/P360 Memory Scanners Product Reference GuideMSI Plessey Check DigitsThese check digits at the end of the bar code verify the integrity of the

Strona 42 - Right Wrong

5-77Parameter MenusTransmit MSI Plessey Check DigitScan the appropriate bar code below to transmit the data with or without the check digit.TRANSMIT M

Strona 43 - Te s t S y m b o l s

5-78P460/P360 Memory Scanners Product Reference GuideMSI Plessey Check Digit AlgorithmWhen the two MSI Plessey check digits option is selected, an add

Strona 44 - Symbol Technologies, Inc

5-79Parameter MenusEnable/Disable PDF417Scan a bar code below to enable or disable PDF417 scanning.Note:PDF417 parameters are available only on the 2D

Strona 45

5-80P460/P360 Memory Scanners Product Reference GuidePDF417 Scanning ModeThis parameter allows you to select one of the following scanning mode option

Strona 46 - Depth of Field

xiiiAbout This ManualIf you purchased your Symbol product from a Symbol Business Partner, contact that Business Partner for service.WarrantySymbol Tec

Strona 47

5-81Parameter Menus3. If you make an error, or wish to change your selection, scan CANCEL.Raster Height (Default 15)Raster Expansion Speed (Default 11

Strona 48 - Keypad Operation

5-82P460/P360 Memory Scanners Product Reference GuideProgrammable Raster Height And Raster Expansion Speed (Continued)1234567890Cancel

Strona 49

5-83Parameter MenusAiming ModeThis parameter allows you to select either an aiming dot or slab raster for aiming.Select the aiming mode.Note:Aiming mo

Strona 50 - Troubleshooting

5-84P460/P360 Memory Scanners Product Reference GuideEnable/Disable MicroPDFScan a bar code below to enable or disable MicroPDF417 scanning.Enable MIC

Strona 51 - You Should

5-85Parameter MenusCode 128 EmulationWhen this parameter is enabled, the scanner transmits data from certain MicroPDF417 symbols as if it was encoded

Strona 52 - Chapter 4

5-86P460/P360 Memory Scanners Product Reference GuideUCC/EAN-128 EmulationCertain MicroPDF417 symbols can be “linked” with a linear symbol during tran

Strona 53 - Replacing the Battery

5-87Parameter MenusMacro PDF Features This section discusses programmable Macro PDF features fully supported by the scanner. Macro PDF is a special fe

Strona 54 - Accessories

5-88P460/P360 Memory Scanners Product Reference GuideMacro PDF Transmit / Decode Mode SymbolsSelect only one of the four options below for handling th

Strona 55 - Technical Specifications

5-89Parameter MenusMacro PDF Transmit / Decode Mode Symbols (Continued)Buffer All Symbols / Transmit When CompleteBuffer Scans Out Of Order/Transmit S

Strona 56

5-90P460/P360 Memory Scanners Product Reference GuideTransmit Symbols in Codeword FormatEnabling this activates transmission of each PDF symbol as dir

Strona 57 - Pin-outs

xivP460/P360 Memory Scanners Product Reference GuideWarranty Coverage and ProcedureDuring the warranty period, Symbol will repair or replace defective

Strona 58 - Table 4-5. Scanner Pin-outs

5-91Parameter MenusTransmit Unknown CodewordsThis enables using the output codeword format for transmitting any non-GLI or non-macro PDF codeword. If

Strona 59 - Beeper Indications

5-92P460/P360 Memory Scanners Product Reference GuideEscape CharactersThis enables the backslash (\) character as an Escape character for systems that

Strona 60 - Chapter 5

5-93Parameter MenusDelete Character Set ECIsThis parameter enables the scanner to delete any escape sequences representing Character Set ECIs (also kn

Strona 61 - Table 5-1. Default Tabl e

5-94P460/P360 Memory Scanners Product Reference GuideECI DecoderThis parameter enables the scanner to interpret any Extended Channel Interpretations (

Strona 62

5-95Parameter MenusTransmit Macro PDF User-Selected FieldsWhen enabled, the following parameters cause transmission of the specified field in subseque

Strona 63

5-96P460/P360 Memory Scanners Product Reference GuideTransmit Block CountTransmit Block Count activates transmission of the block count field. The fie

Strona 64

5-97Parameter MenusTransmit SenderTransmit Sender activates transmission of the sender field. The field character tag is \923\003. For example, the fi

Strona 65

5-98P460/P360 Memory Scanners Product Reference GuideTransmit ChecksumTransmit Checksum activates transmission of the checksum field. The field charac

Strona 66

5-99Parameter MenusTransmit Macro PDF Control HeaderTransmit Macro PDF Control Header activates transmission of the control header, which contains the

Strona 67

5-100P460/P360 Memory Scanners Product Reference GuideFlush Macro BufferThis flushes the buffer of all decoded Macro PDF data stored to that point, tr

Strona 68 - Set Default Parameter

1-1Chapter 1 The Phaser Series ScannerIntroductionThe P460/P360 Memory Scanners bring new flexibility and economy to data capture and data management

Strona 69 - Communication Protocol

5-101Parameter MenusSecurity OptionsLinear Code Type Security LevelsThe Phaser offers four levels of decode security for linear code types (e.g., Code

Strona 70 - Batch/Inventory Application

5-102P460/P360 Memory Scanners Product Reference GuideLinear Code Type Security Level (Continued)Linear Security Level 3Code types other than the foll

Strona 71 - Host Type

5-103Parameter MenusBi-directional RedundancyThis parameter is only valid when a Linear Code Type Security Level (see page 5-101) is enabled. When thi

Strona 72

5-104P460/P360 Memory Scanners Product Reference GuideUPC/EAN Security LevelThe Phaser offers four levels of decode security for UPC/EAN bar codes. In

Strona 73

5-105Parameter MenusUPC/EAN Security Level (Continued)UPC/EAN Security Level 2If you are experiencing mis-decodes of poorly printed bar codes, and the

Strona 74 - Sleep Time

5-106P460/P360 Memory Scanners Product Reference GuideRS-232C ParametersBaud RateBaud rate is the number of bits of data transmitted per second. The s

Strona 75 - Date Separator

5-107Parameter MenusBaud Rate (Continued)BAUD RATE 4800BAUD RATE 9600BAUD RATE 19200BAUD RATE 38400

Strona 76 - Hour Type

5-108P460/P360 Memory Scanners Product Reference GuideParityA parity check bit is the most significant bit of each ASCII coded character. Select the p

Strona 77 - Decimal Separator

5-109Parameter MenusSelect SPACE parity and the parity bit is always 0.SPACEIf no parity is required, select NONE.NONECheck Receive ErrorsSelect wheth

Strona 78 - Date Format

5-110P460/P360 Memory Scanners Product Reference GuideHardware HandshakingThe data interface consists of an RS-232C port. The port has been designed t

Strona 79 - Key Click

1-2P460/P360 Memory Scanners Product Reference GuideThe CradleThe PL 460 and PL 360 Cradles act as a:!stand!communication interface with the host!batt

Strona 80 - Laser On Time

5-111Parameter MenusHardware Handshaking (Continued)Scan the bar code below if no Hardware Handshaking is desired.NONEScan the bar code below to selec

Strona 81 - Scan Stand Options

5-112P460/P360 Memory Scanners Product Reference Guideasserted within two seconds (default), the scanner issues an error indication and discards the d

Strona 82 - Different Symbols

5-113Parameter MenusSoftware Handshaking (Continued)ACK/NAKWhen this option is selected, after transmitting data, the cradle expects either an ACK, Ac

Strona 83

5-114P460/P360 Memory Scanners Product Reference GuideSoftware Handshaking (Continued)XON/XOFFAn XOFF, Transmit Off, character turns the scanner trans

Strona 84 - Beeper Options

5-115Parameter MenusRTS Line StateNote:This only applies to the scanner in corded mode. It has no affect when uploading data through the cradle.Scan t

Strona 85 - Beeper Volume

5-116P460/P360 Memory Scanners Product Reference GuideStop Bit SelectThe stop bit(s) at the end of each transmitted character marks the end of transmi

Strona 86 - Power Detect Beep

5-117Parameter MenusBeep on <BEL>When this parameter is enabled, the scanner beeps when a <BEL> character is detected on the RS-232C seria

Strona 87 - Beep After Good Decode

5-118P460/P360 Memory Scanners Product Reference GuideMCL-Net ParametersMCL-Net Baud RateBaud rate is the number of bits of data transmitted per secon

Strona 88 - Decode Options

5-119Parameter MenusMCL-Net Baud Rate (Continued)BAUD RATE 4800BAUD RATE 9600BAUD RATE 19200BAUD RATE 38400

Strona 89

5-120P460/P360 Memory Scanners Product Reference GuideMCL-Net Hex Addressing ModeScan the appropriate bar code below to set the MCL-Net Hex addressing

Strona 90 - Enable/Disable EAN-8/EAN-13

1-3The Phaser Series ScannerThere are two versions of the Cradle:!PL 460 Cradle: batch retail version!PL 360 Cradle: batch industrial version.Unless o

Strona 91 - Enable/Disable Bookland EAN

5-121Parameter MenusMCL-Net Transmit RetriesScan the following barcode, followed by 2 digits from the numeric barcode section (starting on page 5-122)

Strona 92 - Decode UPC/EAN Supplementals

5-122P460/P360 Memory Scanners Product Reference GuideNumeric Bar CodesFor parameters requiring specific numeric values, scan the appropriately number

Strona 93 - SUPPLEMENTAL REDUNDANCY

5-123Parameter MenusNumeric Bar Codes (Continued)56789

Strona 94 - UPC-E, or UPC-E1 check digit

5-124P460/P360 Memory Scanners Product Reference GuideNumeric Bar Codes (Continued)CancelIf you make an error, or wish to change your selection, scan

Strona 95 - UPC-A Preamble

A-1Appendix ABar Code InformationUCC/EAN-128UCC/EAN-128 is a convention for printing data fields with standard Code 128 bar code symbols. UCC/EAN-128

Strona 96 - UPC-E Preamble

A-2P460/P360 Memory Scanners Product Reference GuideTable A-1. Reading Standard Code128 & UCC/EAN 128Standard Code 128UCC/EAN-128 Effect and Examp

Strona 97 - UPC-E1 Preamble

A-3Bar Code InformationAIM Code IdentifiersEach AIM Code Identifier contains the three-character string ]cm where:] = Flag Character (ASCII 93)c = Cod

Strona 98 - Convert UPC-E to UPC-A

A-4P460/P360 Memory Scanners Product Reference GuideThe modifier character is the sum of the applicable option values based on the following table.Tab

Strona 99 - Convert UPC-E1 to UPC-A

A-5Bar Code InformationCodabar 0 No check digit processing.1 Reader has checked check digit.3 Reader has stripped check digit before transmission.Exam

Strona 100 - EAN Zero Extend

A-6P460/P360 Memory Scanners Product Reference GuideAccording to AIM standards, a UPC with supplemental bar code is transmitted in one of the followin

Strona 101 - Convert EAN-8 to EAN-13 Type

1-4P460/P360 Memory Scanners Product Reference Guide

Strona 102 - UPC/EAN Coupon Code

A-7Bar Code InformationTable A-4. ASCII Character Set ASCIIValueFull ASCII Code 39 Encode Char.Keystroke ASCIIValueFull ASCII Code 39 Encode CharKeys

Strona 103 - Enable/Disable Code 128

A-8P460/P360 Memory Scanners Product Reference GuideASCIIValueFull ASCII Code 39 Encode Char.Keystroke ASCIIValueFull ASCII Code 39 Encode CharKeystro

Strona 104 - Enable/Disable UCC/EAN-128

A-9Bar Code InformationASCIIValueFull ASCII Code 39 Encode Char.Keystroke ASCIIValueFull ASCII Code 39 Encode CharKeystroke1098 +B b 1113 +Q q1099 +C

Strona 105 - Disable ISBT 128

A-10P460/P360 Memory Scanners Product Reference GuideALT Keys Keystroke ALT Keys Keystroke ALT Keys Keystroke2064 ALT 2 2075 ALT K 2086 ALT V2065 ALT

Strona 106 - Enable/Disable Code 39

A-11Bar Code InformationPF Keys Keystroke PF Keys Keystroke PF Keys Keystroke4001 PF 1 4009 PF 9 4017 PF 174002 PF 2 4010 PF 10 4018 PF 184003 PF 3 40

Strona 107 - DISABLE TRIOPTIC CODE 39

A-12P460/P360 Memory Scanners Product Reference GuideNumericKeypadKeystroke NumericKeypadKeystroke NumericKeypadKeystroke6042 * 6049 1 6056 86043 + 60

Strona 108 - Set Lengths for Code 39

B-1Appendix BMessages and Error CodesIntroductionThis chapter contains information on messages displayed on the scanner.MessagesThe scanner displays

Strona 109 - CODE 39 - ANY LENGTH

B-2P460/P360 Memory Scanners Product Reference Guide

Strona 110 - DISABLE CODE 39 CHECK DIGIT

Index-1IndexAabort macro PDF Entry . . . . . . . . . . . . . . . . 5-7accessoriesoptional . . . . . . . . . . . . . . . . . . . . . . . . 4-3requi

Strona 111 - Transmit Code 39 Check Digit

Index-2P460/P360 Memory Scanners Product Reference GuidemacroPDF . . . . . . . . . . . . . . . . . . 5-6, 5-87delete character set ECIs . . . . . 5

Strona 112 - DISABLE CODE 39 FULL ASCII

P460/P360 Memory ScannersProduct Reference Guide70-37690-02Revision AJune 2001

Strona 113 - Convert Code 39 to Code 32

2-1Chapter 2 Set UpIntroductionThis chapter covers the procedures for setting up the Phaser and its accessories.Unpacking Remove the scanner from its

Strona 114 - Code 32 Prefix

Index-3Indexinstalling . . . . . . . . . . . . . . . . . . . . . . . . 2-1carriage return . . . . . . . . . . . . . . . . . . . . . 3-13charge sta

Strona 115 - Enable/Disable Code 93

Index-4P460/P360 Memory Scanners Product Reference Guideescape character . . . . . . . . . . . . . . . . . . . . 5-6Exit System Setup Mode . . . .

Strona 116 - Set Lengths for Code 93

Index-5IndexMCL-Net . . . . . . . . . . . . . . . . . . . . . 3-8, 5-121MCL-Net Baud Rate . . . . . . . . 5-8, 5-118MCL-Net Frame Timeout . . . .

Strona 117 - CODE 93 - ANY LENGTH

Index-6P460/P360 Memory Scanners Product Reference GuideScanning Made Easy . . . . . . . . . . . . . . . . . 1-1Scanning Mode . . . . . . . . . . .

Strona 118 - DISABLE INTERLEAVED 2 OF 5

Index-7IndexVversion . . . . . . . . . . . . . . . . . . . . . . . 3-8, 3-13Wwake up . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2Yya

Strona 119

Index-8P460/P360 Memory Scanners Product Reference Guide

Strona 120 - I 2 of 5 - ANY LENGTH

Thank you for your input—We value your comments.Tell Us What You Think...We’d like to know what you think about this Manual. Please take a moment to f

Strona 122 - Transmit I 2 of 5 Check Digit

70-37690-02Revision A — June 2001Symbol Technologies, Inc. One Symbol Plaza, Holtsville N.Y. 11742-1300P460/P360 Memory Scanners Product Reference Gui

Strona 123 - Convert I 2 of 5 to EAN-13

2-2 P460/P360 Memory Scanners Product Reference Guide2. Plug the modular connector on the cable into the receptacle in the bottom of the Phaser handle

Strona 124 - DISABLE DISCRETE 2 OF 5

2-3Set UpDisconnecting CablesTo disconnect the scanner cable:1. Power down all the devices connected to the scanner.2. Remove the cable by twisting th

Strona 125

2-4 P460/P360 Memory Scanners Product Reference GuideScanner Power OptionsTwo power options are available:!Battery!Power Supply (“Charging”) CableChar

Strona 126 - D 2 of 5 - ANY LENGTH

2-5Set Upwhereas a scanner with a partially charged battery begins charging after approximately 15 minutes. Note that the scanner can be removed from

Strona 127 - Enable/Disable Codabar

2-6 P460/P360 Memory Scanners Product Reference Guide3. For the scanner cable, plug the power supply cable into the power supply port on the housing o

Strona 128 - Set Lengths for Codabar

2-7Set Up4. Plug the Synapse Interface cable into the host device.5. Connect an appropriate power supply to the power receptacle in the Synapse Interf

Strona 129 - CODABAR - ANY LENGTH

2-8 P460/P360 Memory Scanners Product Reference Guide

Strona 130 - CLSI Editing

3-1Chapter 3 OperationIntroductionThis chapter covers how to use the Phaser scanner.Default ApplicationsThe Phaser is shipped from the factory with t

Strona 131 - NOTIS Editing

3-2P460/P360 Memory Scanners Product Reference GuideInitial PowerupAfter a few seconds, the System Banner is replaced by the system initialization scr

Strona 132 - Enable/Disable MSI Plessey

ii 2001 by Symbol Technologies, Inc. All rights reserved.No part of this publication may be reproduced or used in any form, or by any electrical or m

Strona 133 - Set Lengths for MSI Plessey

3-3OperationNumeric Data EntryThis inventory application also allows you to manually enter data if no bar code is present. After keying in data, press

Strona 134 - MSI PLESSEY - ANY LENGTH

3-4P460/P360 Memory Scanners Product Reference GuideEliminating Repetitive ScanningTo eliminate repetitive scanning of identical items, you can enter

Strona 135 - MSI Plessey Check Digits

3-5OperationTo delete stored records:1. Press the <BK> key to select a record to delete. The confirmation screen displays:2. Press Enter to dele

Strona 136 - (DISABLE)

3-6P460/P360 Memory Scanners Product Reference GuidePressing the <BK> key causes the bar code data to be retained in memory. If this is done, an

Strona 137 - MOD 10/MOD 10

3-7OperationThe scan and transmit screen appears as follows:In this mode, scanned bar codes are automatically transmitted to the host in real time. Al

Strona 138 - Enable/Disable PDF417

3-8P460/P360 Memory Scanners Product Reference GuideBelow is the list of available options. Press the Up and Down arrow keys to scroll through them

Strona 139 - PDF417 Scanning Mode

3-9OperationNote:The scanner contains a backup power source to retain the time and date information for up to 24 hours after loss of battery power. If

Strona 140 - Raster Height (Default 15)

3-10P460/P360 Memory Scanners Product Reference GuideOption Description0. Load App / File Puts the scanner into a mode to receive application download

Strona 141 - (Continued)

3-11Operation2. System Code Updates the scanner operating system (Firmware). An RS232 cable is required to download a new operating system. To enter t

Strona 142 - Aiming Mode

3-12P460/P360 Memory Scanners Product Reference GuideParameter ControlParameter Control allows you to control the scanner parameters such as Scan Para

Strona 143 - Enable/Disable MicroPDF

iiiContentsAbout This ManualIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 144 - Code 128 Emulation

3-13OperationErase FileErase File allows you to erase your scanner batch data. All batch data files must be transferred from the scanner to the host b

Strona 145 - UCC/EAN-128 Emulation

3-14P460/P360 Memory Scanners Product Reference GuideNote:Advanced data formatting rules created with ADF Plus are for use with the default applicatio

Strona 146 - Macro PDF Features

3-15Operation• The larger the symbol, the farther away you should hold the scanner.• Hold the scanner closer for symbols with bars that are close toge

Strona 147

3-16P460/P360 Memory Scanners Product Reference GuideHold at an AngleDo not hold the scanner directly over the bar code. Laser light reflecting direct

Strona 148

3-17OperationUPCPDF417Symbol Technologies, Inc.

Strona 149

3-18P460/P360 Memory Scanners Product Reference GuideP460/P360 1D Scanner Decode ZoneFigure 3-3. P460/P360 1D Scanner Decode Zone0 in.0 cm 5 in.12.

Strona 150 - Transmit Unknown Codewords

3-19OperationP460/P360 2D Scanner Decode ZoneFigure 3-4. P460/P360 2D Scanner - 2D Bar Code Decode ZoneIn.cm06.6 mil PDF6.010 mil PDF9.50In. cm

Strona 151 - Escape Characters

3-20P460/P360 Memory Scanners Product Reference GuideFigure 3-5. P460/P360 2D Scanner - 1D Bar Code Decode ZoneIn.cm0UPC15.020 mil20.50In. cmWi

Strona 152 - Delete Character Set ECIs

3-21OperationKeypad OperationInstead of scanning a bar code, you can enter the bar code data using the keypad on the top of the scanner. To enter nume

Strona 153 - ECI Decoder

3-22P460/P360 Memory Scanners Product Reference GuideTo put a decimal point (.) into numeric data, type in the numbers before the decimal point, then

Strona 154 - Transmit File Name

ivP460/P360 Memory Scanners Product Reference GuideRS-232 Power Supply Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 155 - Transmit Time Stamp

3-23OperationTroubleshootingRefer to Appendix B, Messages and Error Codes for additional troubleshooting information.Nothing happens when you follow t

Strona 156 - Transmit Addressee

3-24P460/P360 Memory Scanners Product Reference GuideThe scanner does not decode the bar codes in the system menu section?Your scanner firmware does n

Strona 157 - Transmit File Size

4-1Chapter 4 Maintenance And SpecificationsIntroductionThis chapter explains how to maintain your scanner and the specifications for it.Maintenance!D

Strona 158 - Last Blocker Marker

4-2 P460/P360 Memory Scanners Product Reference Guide2. Remove the battery compartment cover.Figure 4-1. Removing the Battery Compartment Cover3. Sli

Strona 159 - Abort Macro PDF Entry

4-3Maintenance And SpecificationsCharge Status LED IndicationsThe LED indicator on the cradle uses flashing patterns to display the charger status, as

Strona 160 - Security Options

4-4 P460/P360 Memory Scanners Product Reference GuideTechnical SpecificationsTable 4-2. Technical Specifications for P460/P360 1D Scann erItem Descrip

Strona 161 - Linear Security Level 4

4-5Maintenance And SpecificationsTable 4-3. Technical Specifications for P460/P360 2D Scann erItem DescriptionDecode Capability PDF417, MicroPDF417, U

Strona 162 - Bi-directional Redundancy

4-6 P460/P360 Memory Scanners Product Reference GuidePin-outsCradleThe following table shows the pin-outs for both COM1 and COM2 on the cradle.Table 4

Strona 163 - UPC/EAN Security Level

4-7Maintenance And SpecificationsScannerThe following table shows the pin-outs for the scanner.Table 4-5. Scanner Pin-outsPin Scanner1 Not Used2 Power

Strona 164 - UPC/EAN Security Level 3

4-8 P460/P360 Memory Scanners Product Reference GuideBeeper IndicationsTable 4-6. Beeper Indications Beeper Sequence IndicationStandard UseShort high

Strona 165 - RS-232C Parameters

vContentsPin-outs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 166 - Baud Rate (Continued)

5-1Chapter 5 Parameter MenusIntroductionThis chapter has the optional parameter bar codes necessary to program the Phaser scanner.Operational Paramet

Strona 167

5-2P460/P360 Memory Scanners Product Reference GuideThe following table lists the defaults for all parameters. If you wish to change any option, scan

Strona 168 - Check Receive Errors

5-3Parameter MenusBeeper Volume High High 5-26Power Detect Beep Enable Enable 5-27Beep After Good Decode Enable Enable 5-28Decode OptionsTransmit “No

Strona 169 - Hardware Handshaking

5-4P460/P360 Memory Scanners Product Reference GuideUPC-E1 Preamble System Character System Character 5-38Convert UPC-E to A Disable Disable 5-39Conve

Strona 170 - RTS/CTS OPTION 1

5-5Parameter MenusCode 93Code 93 Disable Disable 5-56Set Length(s) for Code 93 4-55 4-55 5-57Interleaved 2 of 5Interleaved 2 of 5 Enable Enable 5-59Se

Strona 171 - Software Handshaking

5-6P460/P360 Memory Scanners Product Reference GuideMSI Plessey Check Digits One One 5-76Transmit MSI Plessey Check DigitDisable Disable 5-77MSI Pless

Strona 172 - ACK/NAK with ENQ

5-7Parameter MenusECIDelete Character Set ECIs N/A Enable 5-93ECI Decoder N/A Enable 5-94Transmit Macro PDF User-Selected FieldTransmit File Name N/A

Strona 173 - Host Serial Response Time-out

5-8P460/P360 Memory Scanners Product Reference GuideRS-232 Host Type Standard Standard 5-12Baud Rate 9600 9600 5-107Parity None None 5-108Check Receiv

Strona 174 - RTS Line State

5-9Parameter MenusSet Default ParameterScanning this bar code returns all parameters to the values listed in Table 5-1.SET ALL DEFAULTS

Strona 175 - ASCII Format

5-10P460/P360 Memory Scanners Product Reference GuideCommunication ProtocolThe bar codes below set the communication protocol used by the default appl

Strona 176 - Intercharacter Delay

viP460/P360 Memory Scanners Product Reference GuideConvert EAN-8 to EAN-13 Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 177 - MCL-Net Parameters

5-11Parameter MenusBatch/Inventory ApplicationThis communication protocol is used when you are ready to transmit your batch records (data collected wh

Strona 178 - MCL-Net Baud Rate (Continued)

5-12P460/P360 Memory Scanners Product Reference GuideHost TypeRS-232 Host TypesMost RS-232C hosts work fine with the default settings, however, three

Strona 179 - Scanner Address

5-13Parameter MenusScan the appropriate bar code below to select an RS-232C Host Interface.STANDARD RS-232CICL RS-232CNIXDORF RS-232C Mode ANIXDORF RS

Strona 180 - MCL-Net Frame Timeout

5-14P460/P360 Memory Scanners Product Reference GuideCode ID Characters for RS232C Host TypesSelecting the ICL, Fujitsu, or Nixdorf RS-232C host inter

Strona 181 - Numeric Bar Codes

5-15Parameter MenusSleep TimeScan the bar code below to select how long the scanner will “stay awake” (not power down) in seconds after a trigger pull

Strona 182 - Numeric Bar Codes (Continued)

5-16P460/P360 Memory Scanners Product Reference GuideDate SeparatorScan the appropriate bar code below to select which separator to use when displayin

Strona 183

5-17Parameter MenusHour TypeScan the appropriate bar code below to select how to display the hour and transmit it to the host device. Choose 12 HOUR (

Strona 184 - Bar Code Information

5-18P460/P360 Memory Scanners Product Reference GuideDecimal SeparatorScan the appropriate bar code below to select what separator to display when you

Strona 185

5-19Parameter MenusDate FormatScan the appropriate bar code below to select how to format the date when it is displayed and transmitted to the host de

Strona 186 - AIM Code Identifiers

5-20P460/P360 Memory Scanners Product Reference GuideKey ClickScan the appropriate bar code below to select whether the keypad click is enabled or not

Strona 187

viiContentsEscape Characters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-92Delet

Strona 188

5-21Parameter MenusLaser On TimeThis parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 seco

Strona 189

5-22P460/P360 Memory Scanners Product Reference GuideScan Stand OptionsThe Scan Stand feature is supported only when the cord is attached to the scann

Strona 190

5-23Parameter MenusSelect the timeouts between decodes for the same or different symbols.1. Scan the option bar code you wish to set.2. Scan two bar c

Strona 191

5-24P460/P360 Memory Scanners Product Reference GuideTimeout Between Decodes (Continued)1234567890Cancel

Strona 192

5-25Parameter MenusBeeper OptionsBeeper ToneScan the appropriate bar code below to select a decode beep frequency (tone). Choose LOW FREQUENCY, MEDIUM

Strona 193

5-26P460/P360 Memory Scanners Product Reference GuideBeeper VolumeScan the appropriate bar code below to select a beeper volume. Choose LOW VOLUME, ME

Strona 194

5-27Parameter MenusPower Detect BeepScan the appropriate barcode below to enable or disable the Power Detection Beep.POWER DETECT BEEP DISABLEDPOWER D

Strona 195

5-28P460/P360 Memory Scanners Product Reference GuideBeep After Good DecodeScan the appropriate bar code below to select whether or not the scanner be

Strona 196 - Messages and Error Codes

5-29Parameter MenusDecode OptionsTransmit “No Read” MessageScan the appropriate bar code below to select whether or not a “No Read” message is transmi

Strona 197

5-30P460/P360 Memory Scanners Product Reference GuideEnable/Disable UPC-E/UPC-A/UPC-E1Scan the appropriate bar code below to enable or disable UPC-E o

Strona 198

viiiP460/P360 Memory Scanners Product Reference GuideMCL-Net Frame Timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 199

5-31Parameter MenusEnable/Disable EAN-8/EAN-13Scan the appropriate bar code below to enable or disable EAN-8 or EAN-13.ENABLE EAN-8DISABLE EAN-8ENABLE

Strona 200

5-32P460/P360 Memory Scanners Product Reference GuideEnable/Disable Bookland EANScan the appropriate bar code below to enable or disable Bookland EAN.

Strona 201

5-33Parameter MenusDecode UPC/EAN SupplementalsSupplementals are characters (either 2 or 5) that are added on according to specific code format conven

Strona 202

5-34P460/P360 Memory Scanners Product Reference GuideDecode UPC/EAN Supplemental RedundancyWith Autodiscriminate UPC/EAN Supplementals selected, this

Strona 203

5-35Parameter MenusTransmit UPC-A/UPC-E/UPC-E1 Check DigitScan the appropriate bar code below to transmit the symbol with or without the UPC-A, UPC-E,

Strona 204

5-36P460/P360 Memory Scanners Product Reference GuideUPC-A PreambleThree options are given for lead-in characters for UPC-A symbols transmitted to the

Strona 205

5-37Parameter MenusUPC-E PreambleThree options are given for lead-in characters for UPC-E symbols transmitted to the host device: Transmit system char

Strona 206 - Tell Us What You Think

5-38P460/P360 Memory Scanners Product Reference GuideUPC-E1 PreambleThree options are given for lead-in characters for UPC-E1 symbols transmitted to t

Strona 207

5-39Parameter MenusConvert UPC-E to UPC-AThis parameter converts UPC-E (zero suppressed) decoded data to UPC-A format before transmission. After conve

Strona 208 - Revision A — June 2001

5-40P460/P360 Memory Scanners Product Reference GuideConvert UPC-E1 to UPC-AThis parameter converts UPC-E1 decoded data to UPC-A format before transmi

Komentarze do niniejszej Instrukcji