Documentation for
KL3201, KL3202 and KL3204
Single-, Two- and Four-Channel Analog Input Terminals
for PT100 (RTD)
Version: 3.2
Date: 2008-03-31
Przeglądanie stron 0
1 2 3 4 5 6 ... 22 23

Podsumowanie treści

Strona 1 - KL3201, KL3202 and KL3204

Documentation for KL3201, KL3202 and KL3204 Single-, Two- and Four-Channel Analog Input Terminals for PT100 (RTD) Version: 3.2 Date:

Strona 2 - Table of contents

Register Description 8 KL3201, KL3202 and KL3204 BK4000 Interbus Coupler The BK4000 Interbus Coupler maps the terminals in the delivery state with

Strona 3 - Foreword

Register Description KL3201, KL3202 and KL3204 9 The main features of the internal data structure are the same for all the intelligent terminals.

Strona 4 - Safety Instructions

Register Description 10 KL3201, KL3202 and KL3204 R13: Data type register Data type register 0x00 Terminal with no valid data type 0x01 Byte ar

Strona 5 - Connection

Register Description KL3201, KL3202 and KL3204 11 Terminal-specific register description Process variables R0: Raw ADC value X_R This register c

Strona 6

Register Description 12 KL3201, KL3202 and KL3204 User parameters R32: Feature register [0x0106] The feature register specifies the terminal's

Strona 7 - Functional description

Register Description KL3201, KL3202 and KL3204 13 If the Siemens output format is selected, the lowest three bits are used for status evaluation

Strona 8

Register Description 14 KL3201, KL3202 and KL3204 Status byte for process data exchange The status byte is transmitted from the terminal to the cont

Strona 9 - Terminal configuration

Register Description KL3201, KL3202 and KL3204 15 KL3202 as resistance input 0 to 1 kΩ If the KL3202 is used for resistance measurements, the fol

Strona 10 - Register Description

Register Description 16 KL3201, KL3202 and KL3204 063Terminal´sregister set64 wordsControl-/status byteUser dataK-BusIf control bit 7=0: input/outp

Strona 11

Appendix KL3201, KL3202 and KL3204 17 Appendix Mapping As already described in the Terminal Configuration section, each Bus Terminal is ma

Strona 12 - R47 to R63

Table of contents KL3201, KL3202 and KL3204 Table of contents 1. Foreword 1 Notes on the documentation 1 Safety Instructions 2 2. Technical data

Strona 13 - 16 bit signed integer

Appendix 18 KL3201, KL3202 and KL3204 KL3202 Conditions Word offset High byte Low byte Complete evaluation: no 0 Ch0 D1 Ch0 D0 Motorola for

Strona 14

Appendix KL3201, KL3202 and KL3204 19 KL3204 Conditions Word offset High byte Low byte Complete evaluation: no 0 Ch0 D1 Ch0 D0 Motorola f

Strona 15 - Control and Status byte

Appendix 20 KL3201, KL3202 and KL3204 Register Table These registers exist once for each channel. Address Denomination Default value R/W Stora

Strona 16

Appendix KL3201, KL3202 and KL3204 21 Support and Service Beckhoff and their partners around the world offer comprehensive service and suppor

Strona 17 - Register communication

Foreword KL3201, KL3202 and KL3204 1 Foreword Notes on the documentation This description is only intended for the use of trained specialists in

Strona 18 - To the bus coupler

Foreword 2 KL3201, KL3202 and KL3204 Safety Instructions State at Delivery All the components are supplied in particular hardware and software con

Strona 19 - Appendix

Technical data KL3201, KL3202 and KL3204 3 Technical data Technical data KL3201 KL3202 KL3204 Number of inputs 1 2 4 Power supply via the

Strona 20

Connection 4 KL3201, KL3202 and KL3204 KL3202 KL3204

Strona 21

Functional description KL3201, KL3202 and KL3204 5 Functional description The KL320x analog input terminals enable resistance sensors to be c

Strona 22 - Register Table

Functional description 6 KL3201, KL3202 and KL3204 Process data The process data that are transferred to the terminal bus are calculated using the

Strona 23 - Support and Service

Terminal configuration KL3201, KL3202 and KL3204 7 Terminal configuration The terminal can be configured and parameterized via the internal r

Komentarze do niniejszej Instrukcji

Brak uwag